# HomeWizard Binding

The HomeWizard binding provides access to several HomeWizard devices by using the local API of those devices.

# Installation

There are two important points of attention: the local API of each device must be enabled and a fixed address must be configured for the devices.

# Local API

The local API of a device can be enabled from the HomeWizard app. Go to Settings in the app, then Meters and select the device you want to enable. On this page enable the local API.

# Fixed Address

The devices support mDNS discovery but the binding does not support that yet. As a result the devices should be reachable through a hostname or a fixed IP address. Since the devices themselves have no option to set a fixed IP address you will need a different solution, for instance having your router hand out an IP address based upon the MAC address of the devices.

# Supported Things

The binding offers three Things, providing support for the P1 meter, the Watermeter and the Energy Socket.

Thing Device Description
p1_wifi_meter Wi-Fi P1 Meter Reads total and current energy usage and total gas usage.
energy_socket Wi-Fi Energy Socket Reads total and current energy usage. Controls power switch, lock and ring brightness.
watermeter Wi-Fi Watermeter Reads total and current water usage.

The HomeWizard kWh meters are not yet officially supported, but they can probably be added as as 'p1_wifi_meter'. However, this has not been tested.

# Discovery

Auto discovery is not yet available for this binding.

# Thing Configuration

All devices can be configured through the web interface.

Parameter Required Default Description
ipAddress * This specifies the IP address (or host name) where the meter can be found.
refreshDelay 5 This specifies the interval in seconds used by the binding to read updated values from the meter.

Note that update rate of the P1 Meter itself depends on the frequency of the telegrams it receives from the Smart Meter. For DSMR5 meters this is generally once per second, for older versions the frequency is much lower.

# Channels

Channel ID Item Type Description Available
active_current Number:ElectricCurrent The combined current in A vor all phases P,E
active_current_l1 Number:ElectricCurrent The active current in A for phase 1. P
active_current_l2 Number:ElectricCurrent The active current in A for phase 2. P
active_current_l3 Number:ElectricCurrent The active current in A for phase 3. P
active_power Number:Power The current net total power in W. It will be below 0 if power is currently being exported. P,E
active_power_l1 Number:Power The current net total power in W for phase 1. P
active_power_l2 Number:Power The current net total power in W for phase 2. P
active_power_l3 Number:Power The current net total power in W for phase 3. P
active_voltage Number:ElectricPotential The active voltage in V P
active_voltage_l1 Number:ElectricPotential The active voltage in V for phase 1. P
active_voltage_l2 Number:ElectricPotential The active voltage in V for phase 2. P
active_voltage_l3 Number:ElectricPotential The active voltage in V for phase 3. P
total_energy_import_t1 Number:Energy The most recently reported total imported energy in kWh by counter 1. P,E
total_energy_import_t2 Number:Energy The most recently reported total imported energy in kWh by counter 2. P
total_energy_export_t1 Number:Energy The most recently reported total exported energy in kWh by counter 1. P,E
total_energy_export_t2 Number:Energy The most recently reported total exported energy in kWh by counter 2. P
total_gas Number:Volume The most recently reported total imported gas in m^3. P
gas_timestamp DateTime The time stamp of the total_gas measurement. P
total_water Number:Volume Total water used. W
current_water Number:VolumetricFlowRate Current water usage. W
power_failures Number The count of long power failures. P
long_power_failures Number the count of any power failures. P
power_switch Switch Controls the power switch of the socket. E
power_lock Switch Controls the lock of the power switch (un/locking both the API and the physical button) E
ring_brightness Number:Dimensionless Controls the brightness of the ring on the socket E

# Full Example

# homewizard.things Example

Thing homewizard:p1_wifi_meter:my_p1 [ ipAddress="192.178.1.67", refreshDelay=5 ]
Thing homewizard:energy_socket:my_socket [ ipAddress="192.178.1.61", refreshDelay=5 ]
Thing homewizard:watermeter:my_water [ ipAddress="192.178.1.27", refreshDelay=15 ]

# homewizard.items Example

Number:Energy Energy_Import_T1 "Imported Energy T1 [%.0f kWh]" {channel="homewizard:p1_wifi_meter:my_meter:total_energy_import_t1" }
Number:Power  Active_Power_L1  "Active Power Phase 1 [%.1f W]" {channel="homewizard:p1_wifi_meter:my_meter:active_power_l1" }