Teleinfo Binding ​

The Teleinfo binding supports an interface to ENEDIS/ERDF Teleinfo protocol for (French) Electricity Meter. This binding works with a Teleinfo modem plugged to the I1 and I2 terminals of your electricity meter. Teleinfo modems can be ordered (see the list of tested hardware below) or build by yourself (see this example).

Teleinfo is a protocol to read many electrical statistics of your electricity meter: instantaneous power consumption, current price period, meter reading... These values can be used to

  • send your meter reading to your electricity provider with a simple copy/paste,
  • improve your rules and minimize electricity costs,
  • check if your subscription is relevant for your needs,
  • monitor your electricity consumption,

TIC Mode ​

There are two different TIC modes, corresponding to two distinct frame formats:

  • Historical TIC mode (older version)

    • Uses a serial transmission rate of 1200 baud.
  • Standard TIC mode (newer version)

    • Uses a serial transmission rate of 9600 baud.
    • Provides more information from the meter.
    • Only available on Linky meters.
    • Offers a faster refresh rate.

The method for changing the TIC mode of a Linky meter is explained in this forum post.

Supported Things ​

Historical TIC Mode ​

Historical TIC mode is the only mode of all telemeters before Linky models and the default mode for Linky telemeters.

The Teleinfo binding provides support for both single-phase and three-phase connection, ICC evolution and the following pricing modes:

  • HCHP mode
  • Base mode
  • Tempo mode
  • EJP mode
Thing typeConnectionPricing modeICC evolution
cbemm_base_electricitymetersingle-phaseBase
cbemm_ejp_electricitymetersingle-phaseEJP
cbemm_hc_electricitymetersingle-phaseHCHP
cbemm_tempo_electricitymetersingle-phaseTempo
cbemm_evolution_icc_base_electricitymetersingle-phaseBase[x]
cbemm_evolution_icc_ejp_electricitymetersingle-phaseEJP[x]
cbemm_evolution_icc_hc_electricitymetersingle-phaseHCHP[x]
cbemm_evolution_icc_tempo_electricitymetersingle-phaseTempo[x]
cbetm_base_electricitymeterthree-phaseBase
cbetm_ejp_electricitymeterthree-phaseEJP
cbetm_hc_electricitymeterthree-phaseHCHP
cbetm_tempo_electricitymeterthree-phaseTempo

Standard TIC Mode ​

Linky telemeters add a new Standard mode with more detailed information but still provide information on the legacy format under the Historical denomination.

Standard mode doesn't depend on the pricing options, but it adds some useful information for electricity producers.

Thing typeConnectionProducer mode
lsmm_electricitymetersingle-phase
lsmm_prod_electricitymetersingle-phase[x]
lstm_electricitymeterthree-phase
lstm_prod_electricitymeterthree-phase[x]

Bridge ​

Consumption data can be retrieved directly from your electricity meter (Linky or older “blue” meters). More information about the Teleinfo protocol is available here: Teleinfo protocol

To do this, the Teleinfo output must be connected to your openHAB server. This is typically done by connecting a Teleinfo modem to the I1 and I2 terminals of your electricity meter.

There are two main ways to achieve this:

  • Direct connection: using a Teleinfo-to-serial modem connected directly to the meter (typically providing data with a granularity of 2 to 5 seconds).
  • Remote connection: using an ERL dongle installed in the meter (typically providing data with a granularity of around 1 minute).

Before the binding can be used, a controller must be configured. Currently, two types of controllers are supported: serial and D2L.

Remote controller connections may use different technologies to transmit the Teleinfo frames. This binding has been tested with a D2L ERL, which uses Wi-Fi to send the frames over a TCP/IP connection.

However, some ERLs use other radio technologies, such as:

  • 433 MHz transmission
  • LoRa or Sigfox (long-range, low-bandwidth networks)
  • KNX
  • Zigbee

At the moment, the binding supports Wi-Fi/D2L devices only. Support for 433 MHz transmission may be added in the future.

KNX and Zigbee are out of scope, as they already have dedicated openHAB bindings.

Serial Bridge ​

Select Teleinfo Serial Controller and enter the serial port.

If you want to place the Teleinfo modem apart from your openHAB server, you can forward its serial messages over TCP/IP (ser2net). In this case you have to define the serial port of your Teleinfo modem like this rfc2217://ip:port. When using ser2net make sure to use telnet instead of raw in the ser2net config file.

ParameterMeaningPossible values
serialportPath to the serial controller/dev/ttyXXXX, rfc2217://ip:port
ticModeTIC modeSTANDARD, HISTORICAL (default)
adcoElectricity meter identifier12 digits number
verifyChecksumIf we check the checksum of the Teleinfo frametrue, false (default=true)
autoRepairInvalidADPSgroupLineIf we try to repair corrupted frametrue, false (default=true)

D2L Bridge ​

The D2L bridge will open a TCP port, listen on it, and wait for Teleinfo frames. If you have multiple meters, you can use a single port for all of them. The bridge will decode the ID of the D2L device sending the frame and dispatch it to the corresponding thing.

ParameterSampleDescription
listenningPort7845The tcp port we will listen for Teleinfo frame coming from D2L
encryptionKeysidd2l:appKey:ivKey;idd2l:appKey:ivKey;The key use by your D2L ERL

EncryptionKeys must be filled with the key assigned to your D2L.
You can put multiple encryptionKeys separate by ";". It will be usefull if you have multiple D2L module.

Each encryptionKey must have this format : idd2l:appKey:ivKey
You can find the idd2l on D2L sticker.
You will have to ask the appKey and ivKey to eesmart support: support@eesmart.fr

Discovery ​

This binding provides a discovery service only for things. Once the bridge added, electricity meters will automatically appear after starting discovery. They meter will have a default label [MeterType] ADCO #adco where #adco is your electricity meter identifier. For D2L-connected meters, you will need to enter the encryptionKey on the D2L bridge previous the discovery phase.

Channels ​

Historical TIC Mode ​

Channel availability depends on the electricity connection (single or three-phase) and on the pricing mode (Base, HCHP, EJP or Tempo).

ChannelTypeDescriptionConnectionMode
isouscNumber:ElectricCurrentSubscribed electric currentAllAll
ptecStringCurrent pricing periodAllAll
imaxNumber:ElectricCurrentMaximum consumed electric currentSingle-phaseAll
imax1Number:ElectricCurrentMaximum consumed electric current on phase 1Three-phaseAll
imax2Number:ElectricCurrentMaximum consumed electric current on phase 2Three-phaseAll
imax3Number:ElectricCurrentMaximum consumed electric current on phase 3Three-phaseAll
adpsNumber:ElectricCurrentExcess electric current warningSingle-phaseAll
adir1Number:ElectricCurrentExcess electric current on phase 1 warningThree-phaseAll
adir2Number:ElectricCurrentExcess electric current on phase 2 warningThree-phaseAll
adir3Number:ElectricCurrentExcess electric current on phase 3 warningThree-phaseAll
iinstNumber:ElectricCurrentInstantaneous electric currentSingle-phaseAll
iinst1Number:ElectricCurrentInstantaneous electric current on phase 1Three-phaseAll
iinst2Number:ElectricCurrentInstantaneous electric current on phase 2Three-phaseAll
iinst3Number:ElectricCurrentInstantaneous electric current on phase 3Three-phaseAll
ppotStringElectrical potential presenceThree-phaseAll
pmaxNumber:EnergyMaximum consumed electric power on all phasesThree-phaseAll
pappNumber:PowerInstantaneous apparent powerThree-phase, single-phase (ICC evolution only)All
hhphcStringPricing schedule groupAllHCHP
hchcNumber:EnergyTotal consumed energy at low rate pricingAllHCHP
hchpNumber:EnergyTotal consumed energy at high rate pricingAllHCHP
baseNumber:EnergyTotal consumed energyAllBase
ejphnNumber:EnergyTotal consumed energy at low rate pricingAllEJP
ejphpmNumber:EnergyTotal consumed energy at high rate pricingAllEJP
bbrhcjbNumber:EnergyTotal consumed energy at low rate pricing on blue daysAllTempo
bbrhpjbNumber:EnergyTotal consumed energy at high rate pricing on blue daysAllTempo
bbrhcjwNumber:EnergyTotal consumed energy at low rate pricing on white daysAllTempo
bbrhpjwNumber:EnergyTotal consumed energy at high rate pricing on white daysAllTempo
bbrhcjrNumber:EnergyTotal consumed energy at low rate pricing on red daysAllTempo
bbrhpjrNumber:EnergyTotal consumed energy at high rate pricing on red daysAllTempo
pejpNumber:TimePrior notice to EJP startAllEJP
demainStringFollowing day colorAllTempo

Standard TIC Mode ​

Common channels ​

The following channels are available on all Linky telemeters in standard TIC mode.

ChannelTypeDescription
commonLSMGroup#ngtfStringProvider schedule name
commonLSMGroup#ltarfStringCurrent pricing label
commonLSMGroup#eastNumber:EnergyTotal active energy withdrawn
commonLSMGroup#easf_XX_Number:EnergyActive energy withdrawn from provider on index XX, XX in {01,...,10}
commonLSMGroup#easd_XX_Number:EnergyActive energy withdrawn from distributor on index XX, XX in {01,...,04}
commonLSMGroup#irms1Number:ElectricCurrentRMS Current on phase 1
commonLSMGroup#urms1Number:PotentialRMS Voltage on phase 1
commonLSMGroup#prefNumber:PowerReference apparent power
commonLSMGroup#pcoupNumber:PowerApparent power rupture capacity
commonLSMGroup#sinstsNumber:PowerInstantaneous withdrawn apparent power
commonLSMGroup#smaxsnNumber:PowerMaximum withdrawn apparent power of the day
commonLSMGroup#smaxsnMinus1Number:PowerMaximum withdrawn apparent power of the previous day
commonLSMGroup#ccasnNumber:PowerActive charge point N
commonLSMGroup#ccasnMinus1Number:PowerActive charge point N-1
commonLSMGroup#umoy1Number:PotentialMean Voltage on phase 1
commonLSMGroup#dpm_X_StringStart of mobile peak period X, X in {1,2,3}
commonLSMGroup#fpm_X_StringEnd of mobile peak period X, X in {1,2,3}
commonLSMGroup#msg1StringShort message
commonLSMGroup#msg2StringVery short message
commonLSMGroup#ntarfStringIndex of current pricing
commonLSMGroup#njourfStringNumber of current provider schedule
commonLSMGroup#njourfPlus1StringNumber of next day provider schedule
commonLSMGroup#pjourfPlus1StringProfile of next day provider schedule
commonLSMGroup#ppointeStringProfile of next rush day
commonLSMGroup#dateDateTimeDate and Time
commonLSMGroup#smaxsnDateDateTimeTimestamp of SMAXSN value
commonLSMGroup#smaxsnMinus1DateDateTimeTimestamp of SMAXSN-1 value
commonLSMGroup#ccasnDateDateTimeTimestamp of CCASN value
commonLSMGroup#ccasnMinus1DateDateTimeTimestamp of CCASN-1 value
commonLSMGroup#umoy1DateDateTimeTimestamp of UMOY1 value
commonLSMGroup#dpm_X_DateDateTimeDate of DPM_X_, X in {1,2,3}
commonLSMGroup#fpm_X_DateDateTimeDate of FPM_X_, X in {1,2,3}
commonLSMGroup#relais_X_Switchstate of relais X, X in {1,...,8}
commonLSMGroup#irms1fcurrentFloating value for Irms1
commonLSMGroup#cosphipowerFactorChannel to feed external cosPhi calculation
commonLSMGroup#sactivepowerActive power calculate from apparent power and Cosphi
commonLSMGroup#sreactivepowerReactive power calculate from apparent power and Cosphi
commonLSMGroup#contac-seccontactStge decode : contact Sec Value
commonLSMGroup#cut-offcutoffStge decode : of cutoff
commonLSMGroup#cachecontactStge decode : linky cache state
commonLSMGroup#over-voltageover-voltage-stateStge decode : overvoltage state
commonLSMGroup#exceeding-powerexceeding-power-stateStge decode : exceding power state
commonLSMGroup#functionfunctionStge decode : function
commonLSMGroup#directiondirectionStge decode : direction
commonLSMGroup#supplier-raterateStge decode : supplier rate index
commonLSMGroup#distributor-raterateStge decode : distributor rate index
commonLSMGroup#clockcontactStge decode : clock state
commonLSMGroup#plcplcStge decode : PLC
commonLSMGroup#outputcomoutputcomStateStge decode : Output com state
commonLSMGroup#plc-stateplcStateStge decode : PLC state
commonLSMGroup#plc-synchrosynchroPlcStateStge decode : PLC Synchro state
commonLSMGroup#tempo-todaytempoStge decode : Today tempo color
commonLSMGroup#tempo-tomorrowtempoStge decode : Tomorrow tempo color
commonLSMGroup#advice-moving-tipsmovingTipsStge decode : Advice of moving tips
commonLSMGroup#moving-tipsmovingTipsStge decode : Current moving tips
commonLSMGroup#pjourf1-plus1StringPjourf decode : Slot 1
commonLSMGroup#pjourf2-plus1StringPjourf decode : Slot 2
commonLSMGroup#pjourf3-plus1StringPjourf decode : Slot 3
commonLSMGroup#pjourf4-plus1StringPjourf decode : Slot 4
commonLSMGroup#pjourf5-plus1StringPjourf decode : Slot 5
commonLSMGroup#pjourf6-plus1StringPjourf decode : Slot 6
commonLSMGroup#pjourf7-plus1StringPjourf decode : Slot 7
commonLSMGroup#pjourf8-plus1StringPjourf decode : Slot 8
commonLSMGroup#ppointe1StringPPointe decode : Slot 1
commonLSMGroup#ppointe2StringPPointe decode : Slot 2
commonLSMGroup#ppointe3StringPPointe decode : Slot 3
commonLSMGroup#ppointe4StringPPointe decode : Slot 4
commonLSMGroup#ppointe5StringPPointe decode : Slot 5
commonLSMGroup#ppointe6StringPPointe decode : Slot 6
commonLSMGroup#ppointe7StringPPointe decode : Slot 7
commonLSMGroup#ppointe8StringPPointe decode : Slot 8

Calculated Channels ​

The binding also offer a number of "calculated" channels.

These channels can help decode existing data into more readable content, such as Relais, Stage State, PjourF, and PPointe advice. Additionally, they can provide new values like irms1f, sactive, and sreactive.

  • irms1f provides a more precise value of irms1, calculated as papp / urms1.
  • cosphi is a specific channel designed to receive the cosphi value calculated by an external device.
  • If cosphi is exposed, sactive and sreactive will provide the Active and Reactive power, respectively, derived from Apparent Power and Cosphi.

Note:
Cosphi, Active Power, and Reactive Power are not directly available on Linky meters. Active power is particularly important as it is used to calculate consumption, which is what your supplier bills you for.

How to feed cosphi ?

You will have to create a specific channel Cosphi. First channel will be the one you get your cosphi from. Second one, with profile="follow" will feed the cosphi to teleinfo binding.

dsl
Number CompteurEDF_xxx_Cosphi "Teleinfo Cosphi [%s]" (gTeleinfo) [ "Measurement" ] {
    channel="mqtt:topic:local:CompteurPi1:PFac_ComptGenerale",
    channel="teleinfo:lsmm_electricitymeter:myElectricityMeter:commonLSMGroup#cosphi" [ profile="follow" ]
}

Three Phase Only Channels ​

These channels are available on the following telemeters:

  • lstm_electricitymeter
  • lsmt_prod_electricitymeter
ChannelTypeDescription
threePhasedLSMGroup#irms_X_Number:ElectricCurrentRMS Current on phase X, X in {2,3}
threePhasedLSMGroup#urms_X_Number:PotentialRMS Voltage on phase X, X in {2,3}
threePhasedLSMGroup#umoy_X_Number:PotentialMean Voltage on phase X, X in {2,3}
threePhasedLSMGroup#sinsts_X_Number:PowerInstantaneous withdrawn apparent power on phase X, X in {1,2,3}
threePhasedLSMGroup#smaxsn_X_Number:PowerMaximum withdrawn apparent power of the day on phase X, X in {1,2,3}
commonLSMGroup#umoy_X_DateDateTimeTimestamp of UMOY_X_ value, X in {2,3}
threePhasedLSMGroup#smaxsn_X_Minus1Number:PowerMaximum withdrawn apparent power on the previous day on phase X, X in {1,2,3}
threePhasedLSMGroup#smaxs_X_nDateDateTimeTimestamp of SMAXSN_X_ value, X in {1,2,3}
threePhasedLSMGroup#smaxsn_X_Minus1DateDateTimeTimestamp of SMAXSN_X_-1 value, X in {1,2,3}

Producer Only Channels ​

These channels are available on the following telemeters:

  • lsmm_prod_electricitymeter
  • lsmt_prod_electricitymeter
ChannelTypeDescription
producerLSMGroup#eaitNumber:EnergyTotal active energy injected
producerLSMGroup#erq_X_Number:EnergyTotal reactive energy on index X, X in {1,...,4}
producerLSMGroup#sinstiNumber:EnergyInstantaneous injected apparent power
producerLSMGroup#smaxinNumber:PowerMaximum injected apparent power of the day
producerLSMGroup#smaxinMinus1Number:PowerMaximum injected apparent power of the previous day
producerLSMGroup#ccainNumber:PowerInjected active charge point N
producerLSMGroup#ccainMinus1Number:PowerInjected active charge point N-1
producerLSMGroup#smaxinDateDateTimeTimestamp of SMAXIN value
producerLSMGroup#smaxinMinus1DateDateTimeTimestamp of SMAXIN-1 value
producerLSMGroup#ccainDateDateTimeTimestamp of CCAIN value
producerLSMGroup#ccainMinus1DateDateTimeTimestamp of CCAIN-1 value

Full Example ​

Historical TIC Mode ​

The following things file declare a serial USB controller on /dev/ttyUSB0 for a Single-phase Electricity meter with HC/HP option - CBEMM Evolution ICC and adco 031528042289:

dsl
Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0" ] {
    Thing cbemm_evolution_icc_hc_electricitymeter myElectricityMeter [ adco="031528042289"]
}

adco is a 12-digit number written on the electricity meter (There might be two additional digits on the electricity meter, in this case the two last digits must be omitted to obtain 12 digits). The first 6 digits of adco can also be retrieved by pushing 6 times the selection button of your electricity meter, and the last 6 digits by pushing the defilement button.

This items file links some supported channels to items:

dsl
Number:Power TLInfoEDF_PAPP "PAPP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:papp"}
Number:ElectricCurrent TLInfoEDF_ISOUSC "ISOUSC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:isousc"}
String TLInfoEDF_PTEC "PTEC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:ptec"}
Number:ElectricCurrent TLInfoEDF_IMAX "IMAX" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:imax"}
Number:ElectricCurrent TLInfoEDF_ADPS "ADPS" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:adps"}
Number:ElectricCurrent TLInfoEDF_IINST "IINST" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:iinst"}
Number:Energy TLInfoEDF_HCHC "HCHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchc"}
Number:Energy TLInfoEDF_HCHP "HCHP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchp"}
String TLInfoEDF_HHPHC "HHPHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hhphc"}

Standard TIC Mode ​

The following things file declare a serial USB controller on /dev/ttyUSB0 for a Linky Single-phase Electricity meter in standard TIC mode and adsc 031528042289:

dsl
Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0", ticMode="STANDARD" ] {
    Thing lsmm_electricitymeter myElectricityMeter [ adco="031528042289"]
}

This items file links some supported channels to items:

dsl
Number:Power TLInfoEDF_SINSTS "SINSTS" <energy> ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#sinsts"}
Number:ElectricCurrent TLInfoEDF_PREF "PREF" <energy> ["Measurement","Power"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#pref"}
String TLInfoEDF_LTARF "LTARF" <energy> ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ltarf"}
Number:ElectricCurrent TLInfoEDF_SMAXSN "SMAXSN" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsn"}
Number:ElectricCurrent TLInfoEDF_IRMS1 "IRMS1" <energy> ["Measurement","Current"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#irms1"}
Number:Energy TLInfoEDF_EASF01 "EASF01" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf01"}
Number:Energy TLInfoEDF_EASF02 "EASF02" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#easf02"}
String TLInfoEDF_NGTF "NGTF" <energy> ["Status"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#ngtf"}
DateTime TLInfoEDF_SMAXSN_DATE "SMAXSN_DATE" <energy> ["Measurement","Energy"] {channel="teleinfo:lsmm_electricitymeter:teleinfoUSB:myElectricityMeter:commonLSMGroup#smaxsnDate"}

Standard TIC Mode With D2l ​

The following things file declare a D2L controller listenning on tcp port 7845 for a Linky Single-phase Electricity meter in standard TIC mode and adsc 031528042289:

dsl
Bridge teleinfo:d2lcontroller:teleinfoD2L "D2lBridge" [ listenningPort="7845"] {
    Thing lsmm_electricitymeter myElectricityMeter [ adco="031528042289" ]
}

Tested Hardware ​

The Teleinfo binding has been successfully validated with below hardware configuration:

Serial interfacePower Energy Meter modelMode(s)TIC mode
GCE Electronics USB Teleinfo module (more details)Actaris A14C5Single-phase HCHP & BaseHistorical
Cartelectronic USB Teleinfo modem (more details)Sagem S10C4Single-phase HCHPHistorical
GCE Electronics USB Teleinfo module (more details)LinkySingle-phase HCHPStandard
Cartelectronic USB Teleinfo modem (more details)LinkyThree-phase TEMPOStandard

You can also build a Teleinfo modem by yourself (see this example).

Wifi interfacePower Energy Meter modelMode(s)TIC mode
D2LLinkySingle-phase TEMPOStandard(more details)

Verify Communication ​

The communication can be verified using software like picocom

picocom -b 9600 -d 7 -p e -f n /dev/ttyUSB1 (for Standard mode) picocom -b 1200 -d 7 -p e -f n /dev/ttyUSB1 (for Historical mode)

After a few seconds, you should see Linky frame displayed in your terminal

java
ADSC        81187xxxxxx             M
VTIC        02                      J
DATE        H250314152111           ;
NGTF        TEMPO                   F
LTARF       HP  BLEU                +
EAST        120684765               6
EASF01      083957312               H
EASF02      031765917               J
EASF03      001219877               G
EASF04      002681581               D
EASF05      000607543               ?
EASF06      000452535               ?
EASF07      000000000               (
EASF08      000000000               )
EASF09      000000000               *
EASF10      000000000               "
EASD01      076241272               ?
EASD02      033890466               H
EASD03      003663842               B
EASD04      006889185               P
IRMS1       006                     4
URMS1       233                     B
PREF        12                      B
PCOUP       12                      \
SINSTS      01389                   [
SMAXSN      H250314052302   07720   8
SMAXSN-1    H250308233739   09340   (
CCASN       H250314150000   05090   >
CCASN-1     H250314143000   06668   *
UMOY1       H250314152000   231     +
STGE        013AC401                R
MSG1        PAS DE          MESSAGE <
PRM         2145499yyyyyyyy         4
RELAIS      000                     B
NTARF       02                      O
NJOURF      00                      &  
NJOURF+1    00                      B
PJOURF+1    00004001 06004002 16004001 NONUTILE NONUTILE NONUTILE NONUTILE NONUTILE NONUTILE NONUTILE NONUTILE      1