Skip to content

Bosch Smart Home Binding ​

Binding for Bosch Smart Home devices.

Supported Things ​

Smart Home Controller ​

The Smart Home Controller is the central hub that allows you to monitor and control your smart home devices from one place.

Bridge Type ID: shc

Channel IDItem TypeWritableDescription
scenario-triggeredStringnoName of the triggered scenario (e.g. by the Universal Switch Flex)
trigger-scenarioStringyesName of a scenario to be triggered on the Bosch Smart Home Controller.

In-Wall Switch ​

A simple light control.

Thing Type ID: in-wall-switch

Channel IDItem TypeWritableDescription
power-switchSwitchyesCurrent state of the switch.
power-consumptionNumber:PowernoCurrent power consumption (W) of the device.
energy-consumptionNumber:EnergynoCumulated energy consumption (Wh) of the device.

Compact Smart Plug ​

A compact smart plug with energy monitoring capabilities.

Thing Type ID: smart-plug-compact

Channel IDItem TypeWritableDescription
power-switchSwitchyesCurrent state of the switch.
power-consumptionNumber:PowernoCurrent power consumption (W) of the device.
energy-consumptionNumber:EnergynoCumulated energy consumption (Wh) of the device.

Compact Smart Plug [+M] ​

A compact smart plug with energy monitoring capabilities. This version of the plug supports the Matter standard.

Thing Type ID: smart-plug-compact-matter

Channel IDItem TypeWritableDescription
power-switchSwitchyesCurrent state of the switch.
power-consumptionNumber:PowernoCurrent power consumption (W) of the device.
energy-consumptionNumber:EnergynoCumulated energy consumption (Wh) of the device.

Dimmer ​

Smart dimmer capable of controlling any dimmable lamp.

Thing Type ID: dimmer

Channel IDItem TypeWritableDescription
power-switchSwitchyesCurrent state of the switch.
brightnessDimmeryesRegulates the brightness on a percentage scale from 0 to 100%.
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
child-protectionSwitchyesIndicates whether the child protection is active.

Twinguard Smoke Detector ​

The Twinguard smoke detector warns you in case of fire and constantly monitors the air.

Thing Type ID: twinguard

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
temperature-ratingStringnoRating of the currently measured temperature.
humidityNumber:DimensionlessnoCurrent measured humidity (0 to 100).
humidity-ratingStringnoRating of current measured humidity.
purityNumber:DimensionlessnoPurity of the air (ppm). Range from 500 to 5500 ppm. A higher value indicates a higher pollution.
purity-ratingStringnoRating of current measured purity.
air-descriptionStringnoOverall description of the air quality.
combined-ratingStringnoCombined rating of the air quality.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
smoke-checkStringyesState of the smoke check. Also used to request a new smoke check.

Door/Window Contact ​

Detects open windows and doors.

Thing Type ID: window-contact

Channel IDItem TypeWritableDescription
contactContactnoContact state of the device.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).

Door/Window Contact II ​

Detects open windows and doors and features an additional button.

Thing Type ID: window-contact-2

Channel IDItem TypeWritableDescription
contactContactnoContact state of the device.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
bypassSwitchnoIndicates whether the device is currently bypassed. Possible values are ON,OFF and UNDEF if the bypass state cannot be determined.
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).

Door/Window Contact II Plus ​

Detects open windows and doors, provides a configurable button and a vibration sensor.

Thing Type ID: window-contact-2-plus

Channel IDItem TypeWritableDescription
contactContactnoContact state of the device.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
bypassSwitchnoIndicates whether the device is currently bypassed. Possible values are ON,OFF and UNDEF if the bypass state cannot be determined.
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
vibration-sensor-enabledSwitchyesChannel to enable or disable the vibration sensor.
vibration-sensor-sensitivityStringyesThe sensitivity of the vibration sensor. Possible values are VERY_HIGH, HIGH, MEDIUM, LOW and VERY_LOW.
vibration-sensor-stateStringnoIndicates whether vibrations were detected by the sensor. Possible values are NO_VIBRATION, VIBRATION_DETECTED and UNKNOWN.

Door/Window Contact II [+M] ​

Detects open windows and doors and features an additional button. This version of the sensor supports the Matter standard.

Thing Type ID: window-contact-2-matter

Channel IDItem TypeWritableDescription
contactContactnoContact state of the device.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
bypassSwitchnoIndicates whether the device is currently bypassed. Possible values are ON,OFF and UNDEF if the bypass state cannot be determined.
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).

Light Control II ​

This thing type is used if Light/Shutter Control II devices are configured as light controls.

Thing Type ID: light-control-2

Channel IDItem TypeWritableDescription
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
power-consumptionNumber:PowernoCurrent power consumption (W) of the device.
energy-consumptionNumber:EnergynoCumulated energy consumption (Wh) of the device.
power-switch-1SwitchyesSwitches the light on or off (circuit 1).
child-protection-1SwitchyesIndicates whether the child protection is active (circuit 1).
power-switch-2SwitchyesSwitches the light on or off (circuit 2).
child-protection-2SwitchyesIndicates whether the child protection is active (circuit 2).

Motion Detector ​

Detects every movement through an intelligent combination of passive infra-red technology and an additional temperature sensor.

Thing Type ID: motion-detector

Channel IDItem TypeWritableDescription
latest-motionDateTimenoThe date of the latest motion.
illuminanceNumbernoThe illuminance level measured by the sensor as integer value in the range 0 to 1000. Note that the sensor only reports the value if the motion light service is activated or if the illuminance state is used in a scenario trigger condition.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).

Presence Simulation ​

Simulates that someone is home.

Thing Type ID: presence-simulation

Channel IDItem TypeWritableDescription
presence-simulation-enabledSwitchyesEnables or disables the presence simulation.

Shutter Control ​

Control of your shutter to take any position you desire.

Thing Type ID: shutter-control

Channel IDItem TypeWritableDescription
levelRollershutteryesCurrent open ratio (0 to 100, Step 0.5).

Shutter Control II ​

This thing type is used if Light/Shutter Control II devices are configured as shutter controls.

Thing Type ID: shutter-control-2

Channel IDItem TypeWritableDescription
levelRollershutteryesCurrent open ratio (0 to 100, Step 0.5).
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
child-protectionSwitchyesIndicates whether the child protection is active.
power-consumptionNumber:PowernoCurrent power consumption (W) of the device.
energy-consumptionNumber:EnergynoCumulated energy consumption (Wh) of the device.

Radiator Thermostat ​

First generation radiator thermostat.

Thing Type ID: thermostat

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
temperature-offsetNumber:TemperatureyesTemperature offset to be added or subtracted from the measured temperature. Value range for Celsius and Kelvin quantities: minimum -5°C / -5 K, maximum +5°C / +5 K. Value range for Fahrenheit quantities: minimum -9°F, maximum +9°F. Step size: 0.1°C. Non-Celsius temperature offsets will be converted to Celsius deltas automatically and rounded to the first decimal digit.
valve-tappet-positionNumber:DimensionlessnoCurrent open ratio of valve tappet (0 to 100).
child-lockSwitchyesIndicates if child lock is active.
silent-modeSwitchyesEnables or disables silent mode on thermostats. When enabled, the battery usage is higher.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).

Radiator Thermostat II ​

Second generation radiator thermostat.

Thing Type ID: thermostat-2

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
temperature-offsetNumber:TemperatureyesTemperature offset to be added or subtracted from the measured temperature. Value range for Celsius and Kelvin quantities: minimum -5°C / -5 K, maximum +5°C / +5 K. Value range for Fahrenheit quantities: minimum -9°F, maximum +9°F. Step size: 0.1°C. Non-Celsius temperature offsets will be converted to Celsius deltas automatically and rounded to the first decimal digit.
valve-tappet-positionNumber:DimensionlessnoCurrent open ratio of valve tappet (0 to 100).
child-lockSwitchyesIndicates if child lock is active.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
display-directionSwitchyesConfigures the display direction. OFF corresponds to NORMAL and ON corresponds to REVERSED.
displayed-temperatureSwitchyesConfigures whether the measured temperature or the setpoint temperature is displayed. OFF corresponds to MEASURED and ON corresponds to SETPOINT.

Radiator Thermostat II [+M] ​

Second generation radiator thermostat with Matter support.

Thing Type ID: thermostat-2-matter

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
temperature-offsetNumber:TemperatureyesTemperature offset to be added or subtracted from the measured temperature. Value range for Celsius and Kelvin quantities: minimum -5°C / -5 K, maximum +5°C / +5 K. Value range for Fahrenheit quantities: minimum -9°F, maximum +9°F. Step size: 0.1°C. Non-Celsius temperature offsets will be converted to Celsius deltas automatically and rounded to the first decimal digit.
valve-tappet-positionNumber:DimensionlessnoCurrent open ratio of valve tappet (0 to 100).
child-lockSwitchyesIndicates if child lock is active.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
display-directionSwitchyesConfigures the display direction. OFF corresponds to NORMAL and ON corresponds to REVERSED.
displayed-temperatureSwitchyesConfigures whether the measured temperature or the setpoint temperature is displayed. OFF corresponds to MEASURED and ON corresponds to SETPOINT.

Climate Control ​

A virtual device which controls up to six Bosch Smart Home radiator thermostats in a room.

Thing Type ID: climate-control

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
setpoint-temperatureNumber:TemperatureyesDesired temperature.

Wall Thermostat ​

Display of the current room temperature as well as the relative humidity in the room.

Thing Type ID: wall-thermostat

Channel IDItem TypeWritableDescription
temperatureNumber:TemperaturenoCurrent measured temperature.
humidityNumber:DimensionlessnoCurrent measured humidity (0 to 100).
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).

Relay ​

The smart switching relay is your universal all-rounder for smart switching.

Thing Type ID: relay

Channel IDItem TypeWritableDescription
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
child-protectionSwitchyesIndicates whether the child protection is active.
power-switchSwitchyesSwitches the relay on or off. Only available if the relay is in power switch mode.
impulse-switchSwitchyesChannel to send impulses by means of ON events. After the time specified by impulse-length, the relay will switch off automatically and the state will be reset to OFF. Only available if the relay is in impulse switch mode.
impulse-lengthNumber:TimeyesChannel to configure how long the relay will stay on after receiving an impulse switch event. If raw numbers (without time unit) are provided, the default unit is tenth seconds (deciseconds), e.g. 15 means 1.5 seconds. If quantities with time units are provided, the quantity will be converted to deciseconds internally, discarding any fraction digits that are more precise than expressible in whole deciseconds (e.g. 1.58 seconds will be converted to 15 ds). Only available if the relay is in impulse switch mode.
instant-of-last-impulseDateTimenoTimestamp indicating when the last impulse was triggered. Only available if the relay is in impulse switch mode.

If the device mode is changed from power switch to impulse switch mode or vice versa, the corresponding thing has to be deleted and re-added in openHAB.

Security Camera 360 ​

Indoor security camera with 360° view and motion detection.

Thing Type ID: security-camera-360

Channel IDItem TypeWritableDescription
privacy-modeSwitchyesIf privacy mode is enabled, the camera is disabled and vice versa.
camera-notificationSwitchyesEnables or disables notifications for the camera.

Security Camera Eyes ​

Outdoor security camera with motion detection and light.

Thing Type ID: security-camera-eyes

Channel IDItem TypeWritableDescription
privacy-modeSwitchyesIf privacy mode is enabled, the camera is disabled and vice versa.
camera-notificationSwitchyesEnables or disables notifications for the camera.

Intrusion Detection System ​

Allows to retrieve notifications in case of intrusions. The system can be armed and disarmed and alarms can be muted.

Thing Type ID: intrusion-detection-system

Channel IDItem TypeWritableDescription
system-availabilitySwitchnoIndicates whether the intrusion detection system is available.
arming-stateStringnoRead-only channel to retrieve the current arming state. Possible values are SYSTEM_ARMING, SYSTEM_ARMED and SYSTEM_DISARMED.
alarm-stateStringnoRead-only channel to retrieve the current alarm state. Possible values are ALARM_OFF, PRE_ALARM, ALARM_ON, ALARM_MUTED and UNKNOWN.
active-configuration-profileStringnoThe name of the active configuration profile used for the intrusion detection system.
arm-actionStringyesArms the intrusion detection system using the given profile ID (default is "0").
disarm-actionSwitchyesDisarms the intrusion detection system when an ON command is received.
mute-actionSwitchyesMutes the alarm when an ON command is received.

Smart Bulb ​

A smart bulb connected to the bridge via Zigbee such as a Ledvance Smart+ bulb.

Thing Type ID: smart-bulb

Channel IDItem TypeWritableDescription
power-switchSwitchyesSwitches the light on or off.
brightnessDimmeryesRegulates the brightness on a percentage scale from 0 to 100%.
colorColoryesThe color of the emitted light.

Smoke Detector ​

The smoke detector warns you in case of fire.

Thing Type ID: smoke-detector

Channel IDItem TypeWritableDescription
alarmStringyesAlarm state of the smoke detector. Possible values to read are: IDLE_OFF, PRIMARY_ALARM, SECONDARY_ALARM and INTRUSION_ALARM. Possible values to write are: INTRUSION_ALARM_ON_REQUESTED and INTRUSION_ALARM_OFF_REQUESTED.
smoke-checkStringyesState of the smoke check. Also used to request a new smoke check.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).

Smoke Detector II ​

The smoke detector warns you in case of fire.

Thing Type ID: smoke-detector-2

Channel IDItem TypeWritableDescription
alarmStringyesAlarm state of the smoke detector. Possible values to read are: IDLE_OFF, PRIMARY_ALARM, SECONDARY_ALARM and INTRUSION_ALARM. Possible values to write are: INTRUSION_ALARM_ON_REQUESTED and INTRUSION_ALARM_OFF_REQUESTED.
smoke-checkStringyesState of the smoke check. Also used to request a new smoke check.
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).

User-defined States ​

User-defined states enable automations to be better adapted to specific needs and everyday situations. Individual states can be activated/deactivated and can be used as triggers, conditions and actions in automations.

Thing Type ID: user-defined-state

Channel IDItem TypeWritableDescription
user-stateSwitchyesSwitches the User-defined state on or off.

Universal Switch ​

A universally configurable switch with two buttons.

Thing Type ID: universal-switch

Channel IDItem TypeWritableDescription
key-codeNumber:DimensionlessnoInteger code of the key that was pressed.
key-nameStringnoName of a key pressed on a device. Possible values for Universal Switch: LOWER_BUTTON, UPPER_BUTTON.
key-event-typeStringnoIndicates how the key was pressed. Possible values are PRESS_SHORT, PRESS_LONG and PRESS_LONG_RELEASED.
key-event-timestampDateTimenoTimestamp indicating when the key was pressed.

Universal Switch II ​

A universally configurable switch with four buttons.

Thing Type ID: universal-switch-2

Channel IDItem TypeWritableDescription
key-codeNumber:DimensionlessnoInteger code of the key that was pressed.
key-nameStringnoName of the key that was pressed. Possible values for Universal Switch II: LOWER_LEFT_BUTTON, LOWER_RIGHT_BUTTON, UPPER_LEFT_BUTTON, UPPER_RIGHT_BUTTON.
key-event-typeStringnoIndicates how the key was pressed. Possible values are PRESS_SHORT, PRESS_LONG and PRESS_LONG_RELEASED.
key-event-timestampDateTimenoTimestamp indicating when the key was pressed.

Water Detector ​

Smart water leakage detector.

Thing Type ID: water-detector

Channel IDItem TypeWritableDescription
battery-levelNumbernoCurrent battery level percentage as integer number. Bosch-specific battery levels are mapped to numbers as follows: OK: 100, LOW_BATTERY: 10, CRITICAL_LOW: 1, CRITICALLY_LOW_BATTERY: 1, NOT_AVAILABLE: UNDEF.
low-batterySwitchnoIndicates whether the battery is low (ON) or OK (OFF).
signal-strengthNumbernoCommunication quality between the device and the Smart Home Controller. Possible values range between 0 (unknown) and 4 (best signal strength).
water-leakageSwitchnoIndicates whether a water leakage was detected.
push-notificationsSwitchyesIndicates whether push notifications are enabled.
acoustic-signalsSwitchyesIndicates whether acoustic signals are enabled.
water-leakage-sensor-checkStringnoProvides the result of the last water leakage sensor check.
sensor-movedTriggernoTriggered when the sensor is moved.

Limitations ​

No major limitation known. Check list of openhab issues with "boshshc"

Discovery ​

Bridge discovery is supported via mDNS. Things discovery is started after successful pairing.

Configuration via configuration files or UI supported too (see below).

Bridge Configuration ​

You need to provide the IP address and the system password of your Bosch Smart Home Controller. The IP address of the controller is visible in the Bosch Smart Home Mobile App (More -> System -> Smart Home Controller) or in your network router UI. The system password is set by you during your initial registration steps in the Bosch Smart Home App.

A keystore file with a self-signed certificate is created automatically. This certificate is used for pairing between the Bridge and the Bosch Smart Home Controller.

On the Smart Home Controller Bridge, paring mode must be enabled after the shc Thing was created:

  • Smart Home Controller: Press and hold the button until the LED starts blinking to enable pairing mode.
  • Smart Home Controller II: Press the button briefly to enable pairing mode.

Getting the device IDs ​

Bosch IDs for found devices are displayed in the openHAB log on bootup (OPENHAB_FOLDER/userdata/logs/openhab.log)

The log can also be called using the following command.

bash
tail -f /var/log/openhab/openhab.log /var/log/openhab/events.log

Alternatively, the log can be viewed using the openHAB Log Viewer (frontail) via http://openhab:9001.

Example:

bash
2023-03-20 20:30:48.026 [INFO ] [g.discovery.internal.PersistentInbox] - Added new thing 'boschshc:security-camera-eyes:yourBridgeName:hdm_Cameras_XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX' to inbox.
2023-03-20 20:30:48.026 [INFO ] [g.discovery.internal.PersistentInbox] - Added new thing 'boschshc:smoke-detector:yourBridgeName:hdm_HomeMaticIP_XXXXXXXXXXXXXXXXXXXXXXXX' to inbox.
2023-03-20 20:30:48.027 [INFO ] [g.discovery.internal.PersistentInbox] - Added new thing 'boschshc:twinguard:yourBridgeName:hdm_ZigBee_XXXXXXXXXXXXXXXX' to inbox.
2023-03-20 20:30:48.028 [INFO ] [g.discovery.internal.PersistentInbox] - Added new thing 'boschshc:smart-bulb:yourBridgeName:hdm_PhilipsHueBridge_HueLight_XXXXXXXXXXXXXXXX-XX_XXXXXXXXXXXX' to inbox.

Thing Configuration ​

You define your Bosch devices by adding them either to a .things file in your $OPENHAB_CONF/things folder like this:

dsl
Bridge boschshc:shc:1 [ ipAddress="192.168.x.y", password="XXXXXXXXXX" ] {
  Thing in-wall-switch bathroom "Bathroom" [ id="hdm:HomeMaticIP:3014F711A000XXXXXXXXXXXX" ]
  Thing in-wall-switch bedroom "Bedroom" [ id="hdm:HomeMaticIP:3014F711A000XXXXXXXXXXXX" ]
  Thing in-wall-switch kitchen "Kitchen" [ id="hdm:HomeMaticIP:3014F711A000XXXXXXXXXXXX" ]
  Thing in-wall-switch corridor "Corridor" [ id="hdm:HomeMaticIP:3014F711A000XXXXXXXXXXXX" ]
  Thing in-wall-switch livingroom "Living Room" [ id="hdm:HomeMaticIP:3014F711A000XXXXXXXXXXXX" ]

  Thing in-wall-switch coffeemachine "Coffee Machine" [ id="hdm:HomeMaticIP:3014F711A0000XXXXXXXXXXXX" ]

  Thing twinguard      tg-corridor    "Twinguard Smoke Detector" [ id="hdm:ZigBee:000d6f000XXXXXXX" ]
  Thing window-contact window-kitchen "Window Kitchen"           [ id="hdm:HomeMaticIP:3014F711A00000XXXXXXXXXX" ]
  Thing window-contact entrance       "Entrance door"            [ id="hdm:HomeMaticIP:3014F711A00000XXXXXXXXXX" ]

  Thing motion-detector  motion-corridor "Bewegungsmelder"      [ id="hdm:ZigBee:000d6f000XXXXXXX" ]
}

Or by adding them via UI: Settings -> Things -> "+" -> Bosch Smart Home Binding.

Item Configuration ​

You define the items which should be linked to your Bosch devices via a .items file in your $OPENHAB_CONF/items folder like this:

dsl
Switch Bosch_Bathroom    "Bath Room"    { channel="boschshc:in-wall-switch:1:bathroom:power-switch" }
Switch Bosch_Bedroom     "Bed Room"     { channel="boschshc:in-wall-switch:1:bedroom:power-switch" }
Switch Bosch_Kitchen     "Kitchen"      { channel="boschshc:in-wall-switch:1:kitchen:power-switch" }
Switch Bosch_Corridor    "Corridor"     { channel="boschshc:in-wall-switch:1:corridor:power-switch" }
Switch Bosch_Living_Room "Living Room"  { channel="boschshc:in-wall-switch:1:livingroom:power-switch" }

Switch Bosch_Lelit       "Lelit"        { channel="boschshc:in-wall-switch:1:coffeemachine:power-switch" }

Or by adding them via UI: Settings -> Items -> "+".