Digiplex/EVO Binding ​

This binding provides integration with Digiplex/EVO alarm systems from Paradox. It utilizes PRT3 module for serial communication.

Supported Things ​

PRT3 Module ​

Before the binding can be used, a serial adapter must be added manually. Select PRT3 Module and enter serial port parameters. Please refer to PRT3 module manual for instructions how to modify baudrate (default setting is 2400)

Discovery ​

Once PRT3 Module is added and communication with the alarm system confirmed by its online status, please start discovery process to automatically discover (and add as new Things) all zones and areas defined in the alarm system.

Binding Configuration ​

There is no binding level configuration required.

Thing Configuration ​

PRT3 Module Configuration ​

The following section lists the PRT3 Module configuration. If using manual configuration in text files, the parameter names are given in the square brackets.

Serial Port [port] ​

Sets the serial port name for the communication with the alarm system

Baud Rate [baudrate] ​

Baud rate to use for serial port communication

Area configuration ​

Refresh time of area status (in seconds) [refreshPeriod] ​

Controls how often area status is refreshed from the alarm system.

Channels ​

PTR3 Module Channels ​

The table below summarizes all the channels available from the PTR3 Module thing.

ChannelDescription
messages_sentCounts the number of messages sent to the module
responses_receivedCounts the number of responses received from the module
events_receivedCounts the number of events received from the module

Zone Channels ​

The table below summarizes all the channels available from the zone thing.

ChannelDescription
statusSimple zone status (open/closed)
extended_statusExtended zone status as a String (Open/Closed/Tampered/Fire Loop Alarm)
alarmInformation whether zone is in alarm (open/closed)
fire_alarmSame as above for fire alarm
supervision_lostInformation whether supervision has been lost (open/closed)
low_batteryLow battery warning (open/closed)

Area Channels ​

The table below summarizes all the channels available from the area thing.

ChannelDescription
statusArea status available as a String
armedSimple (open/closed) information whether zone is armed
zone_in_memoryInformation whether there are zones in the memory (after alarm has been triggered
troubleInformation whether some of the zones are in 'trouble' (malfunctioning)
readyInformation whether area is ready (no open zones)
in_programmingChecks for programming mode enabled
alarmInformation whether area is in alarm
strobeInformation whether area is in strobe alarm
controlChannel for controlling area

User is able to send commands through control channel to arm/quick arm/disarm the zone. Every sent message is followed by the channel state change to either Ok or Failed depending whether command has been accepted by the alarm system. Note that PRT3 module is capable of handling more kinds of messages, but those are not yet supported by this binding. Message format is as follows:

CommandString sent to the control channel
Regular ArmAA<pin>
Force ArmAF<pin>
Stay ArmAS<pin>
Instant ArmAI<pin>
Regular Quick ArmQA
Force Quick ArmQF
Stay Quick ArmQS
Instant Quick ArmQI
DisarmD<pin>

<pin> is your PIN as entered on a keypad.

Note: For security reasons please consider not storing your PIN in openHAB configuration files.

Note2: Please consult your alarm system manual how to enable Quick Arm feature. It is not enabled by default.

For example, the following sitemap item can be used to send commands to the area and receive response status as modified color of a label:

dsl
Switch item=areaControl label="Actions[]" mappings=[QA="Regular Quick Arm",QS="Stay Quick Arm",D1111="Disarm"] labelcolor=[Ok="green",Fail="red"]