Skip to content

Somfy Tahoma Binding ​

This binding integrates the Somfy Tahoma and Somfy Connexoon home automation systems. Any home automation system based on the OverKiz API is potentially supported.

Supported Things ​

Currently these things are supported:

  • bridge (cloud bridge, which can discover gateways, roller shutters, awnings, switches and action groups)
  • gateways (gateway status)
  • gates (control gate, get state)
  • roller shutters (UP, DOWN, STOP control of a roller shutter). IO Homecontrol devices are allowed to set exact position of a shutter (0-100%)
  • blinds (UP, DOWN, STOP control of a blind). IO Homecontrol devices are allowed to set exact position of a blind (0-100%) as well as orientation of slats (0-100%)
  • screens (UP, DOWN, STOP control of a screen). IO Homecontrol devices are allowed to set exact position of a screen (0-100%)
  • garage doors (UP, DOWN, STOP control of a garage door). IO Homecontrol devices are allowed to set exact position of a garage door (0-100%)
  • awnings (UP, DOWN, STOP control of an awning). IO Homecontrol devices are allowed to set exact position of an awning (0-100%)
  • windows (UP, DOWN, STOP control of a window). IO Homecontrol devices are allowed to set exact position of a window (0-100%)
  • pergolas (UP, DOWN, STOP control of a pergola). IO Homecontrol devices are allowed to set exact position of a pergola (0-100%)
  • shutters (OPEN, CLOSE, STOP control of a shutter)
  • on/off switches (connected by RTS, IO protocol or supported by USB stick - z-wave, enocean, ..)
  • light switches (similar to on/off)
  • dimmer lights (light switches with intensity setting)
  • light sensors (luminance value)
  • occupancy sensors (OPEN/CLOSE contact)
  • smoke sensors (OPEN/CLOSE contact, alarm check)
  • contact sensors (OPEN/CLOSE contact)
  • rain sensors (OPEN/CLOSE contact)
  • temperature sensors (get temperature)
  • electricity sensors (get energy consumption)
  • carbon dioxide sensors (get CO2 concentration)
  • noise sensors (get noise)
  • door locks (LOCK/UNLOCK, OPEN/CLOSE commands)
  • heating systems (control temperature, set heating level)
  • valve heating systems (control temperature, derogation mode and temperature)
  • exterior heating systems (set heating level)
  • alarms (both interior/external)
  • pods
  • docks (battery info, siren control)
  • sirens (battery status full/low/normal/verylow, siren control ON/OFF, setting memorized volume)
  • action groups (scenarios which can execute predefined Tahoma group of steps, e.g. send to all roller shutters DOWN command, one by one)
  • thermostats (read status and battery level)
  • water heater system (monitor and control)
  • Yutaki heat pump consisting of heat pump, heating control and hot water tank (controls and a lot of states; it is tested with components RAS-4WHNPE, RWM-4.ONE, DHWT-300S-3.0H2E)

Both Somfy Tahoma and Somfy Connexoon gateways have been confirmed working in the cloud mode.

Discovery ​

To start a discovery, just

  • Add a new bridge Thing.
  • Configure the bridge selecting your cloud portal (<www.tahomalink.com> by default) and setting your email (login) and password to the cloud portal.

If the supplied credentials are correct, the automatic discovery can be used to scan and detect your devices which will appear in your Inbox. If you are missing some device, check the debug log during the discovery and create an issue with the information about an unsupported Thing from the log.

Thing Configuration ​

bridge ​

ParameterParameter IDRequired/OptionalDescription
Cloud portalcloudPortalOptionalCloud portal to connect to
Email addressemailRequiredEmail address for the portal
PasswordpasswordRequiredPassword for the portal
RefreshrefreshOptionalRefresh time for polling events (in seconds)
Status timeoutstatusTimeoutOptionalReconciliation timeout after which the status is refreshed (in seconds)
RetriesretriesOptionalSpecifies the number of retries when command execution
Retry delayretryDelayOptionalDelay in milliseconds between subsequent retries after a command failure
Developer modedevModeOptionalEnables the direct control of your devices over the lan using the local API endpoint
Gateway IPipOptionalLocal IP address of gateway, relevant only if developer mode is enabled
Gateway PINpinOptionalGateway PIN in format ABCD-EFGH-IJKL, relevant only if developer mode is enabled
Local tokentokenOptionalToken for local communication, relevant only if developer mode is enabled

For more information about the developer mode please see https://github.com/Somfy-Developer/Somfy-TaHoma-Developer-Mode. If the gateway ip or pin are not provided, the binding tries to detect it automatically and saves it into the configuration. If the local token is not provided, the binding creates the local token automatically and saves it into the configuration. Please note that the action groups (scenarios) control does not work in local mode due to missing support in the gateway firmware. The gateway support for the developer mode is limited as well, so far Connexoon gateways do not support the developer mode.

gateway ​

ParameterParameter IDRequired/OptionalDescription
Gateway ididRequiredID of your gateway (sometimes called pin)

other devices ​

ParameterParameter IDRequired/OptionalDescription
Device URLurlRequiredThe identifier of the device

To retrieve the url parameter or gateway id, just add the automatically discovered device from your inbox and copy its values from Thing edit page (the url parameter is visible on edit page only). Please see the example below.

Channels ​

ThingChannelNote
bridgeN.Abridge does not expose any channel
gatewaystatusstatus of your gateway
gatewayscenariosused to run the scenarios defined in the cloud portal
gategate_commandused for controlling your gate (open, close, stop, pedestrian)
gategate_stateget state of your gate (open, closed, pedestrian)
gategate_positionget position (0-100%) of your gate (where supported)
roller shutter, shutter, screen, ven. blind, garage door, awning, pergola, curtaincontroldevice controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/MY/STOP + closure 0-100
roller shuttermovingIndicates if the device is currently operating a command
windowcontroldevice controller which reacts to commands UP/DOWN/ON/OFF/OPEN/CLOSE/STOP + closure 0-100
silent roller shuttersilent_controlsimilar to control channel but in silent mode
venetian blind, adjustable slats roller shutter, bioclimatic pergolaorientationpercentual orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS)
venetian blind, up/down venetian blind, adjustable slats roller shutterclosure_orientationpercentual closure and orientation of the blind's slats, it can have value 0-100. For IO Homecontrol devices only (non RTS)
up/down venetian blindtilttilt of the blind's slats, it can have value -5 to 5 (negative or positive tilt). Works even for RTS blinds
adjustable slats roller shutterrockerused for setting the rocker position of the roller shutter, the only position allowing the slats control
bioclimatic pergolaslatsslats state (open/closed)
bioclimatic pergolapergola_commandused for controlling bioclimatic pergola (closeSlats, openSlats, stop)
action groupexecute_actionswitch which reacts to ON command and triggers the predefined Tahoma action
onoff, lightswitchreacts to standard ON/OFF commands
dimmer lightlight_intensitysets/gets intensity of the dimmer light or ON/OFF
smoke sensor, occupancy sensor, contact sensor, water sensor & rain sensorcontactnormal value is CLOSE, changes to OPEN when detection triggered
smoke sensor, occupancy sensor, contact sensor & water sensorsensor_defectindicates the health of the sensor (dead, lowBatter, maintenanceRequired, noDefect)
smoke sensorradio_batterymaintenance radio part battery state (low, normal)
smoke sensorsensor_batterymaintenance sensor part battery state (absence, low, normal)
smoke sensoralarm_checktriggers the smoke sensor's beep check (short, long)
light sensorluminancelight luminance value in luxes
electricity sensorenergy_consumptionenergy consumption value in watts
humidity sensorhumiditycurrent relative humidity
carbon dioxide sensorco2_concentrationCO2 concentration in ppm
noise sensornoisenoise in decibel
dockbattery_statusindicates running on battery (yes/no)
dockbattery_levelremaining battery percentage
docksiren_statusused for controlling and getting siren state (on, off, cyclic)
dockshort_beeptesting of dock's siren - short beep
docklong_beeptesting of dock's siren - long beep
sirenbatterybattery level full/low/normal/verylow
sirenonoffcontrolling siren status ON/OFF
sirenmemorized_volumesetting memorized volume (normal/highest)
podcyclic_buttonpod cyclic button state
podbattery_statuspod battery status state
podlighting_led_pod_modelighting LED pod mod state
interior alarmalarm_commandused for sending commands to Somfy alarm device
interior alarmintrusion_controlused for alarm external intrusion controlling
interior alarm, myfox alarmalarm_statestate of the Somfy alarm
interior alarmtarget_alarm_statetarget state of the Somfy alarm
interior alarm, myfox alarmintrusion_stateintrusion state of the Somfy alarm
external alarmactive_zones_statestate of external alarm active zones
door locklockswitch representing unlocked/locked state
door lockopenswitch representing open/close state
on/off heating systemtarget_heating_leveltarget heating level (off, eco, comfort, frostprotection)
heating systemcurrent_temperaturecurrent temperature of the heating system
heating systemcurrent_statecurrent state of the heating system
heating system, valve heating system, thermostattarget_temperaturetarget temperature of the heating system
heating system, valve heating system, thermostatbattery_levelbattery level of the heating system
valve heating system, thermostatderogation_heating_modederogation heating mode of the thermostat (away, freeze, manual, ...)
valve heating system, thermostatderogated_target_temperaturetarget temperature of the heating system
valve heating systemcurrent_heating_modecurrent heating mode of the thermostatic valve
valve heating systemopen_closed_valvecurrent open/closed state of the thermostatic valve
valve heating systemoperating modeoperating mode of the thermostatic valve
thermostatheating_modestandard heating mode of the thermostat (away, freeze, manual, ...)
thermostatderogation_activationderogation activation state (inactive, active)
exterior heating systemheating_levelheating level of the exterior heating system or ON/OFF
temperature sensortemperaturetemperature reported by the sensor
myfox camera, myfox alarmcloud_statuscloud connection status
myfox camerashuttercontrolling of the camera shutter
myfox alarmmyfox_alarm_commandused for sending commands to Somfy Myfox alarm device
waterheatersystemmiddlewater_temperatureNumber:Temperature indicating the temperature of the water at the middle of the heater
waterheatersystemboost_modeSwitch allowing to enable or disable the booster. When switching to ON, by default, the Boost duration will be set for 1 day.
waterheatersystemaway_modeDefines if away mode is On or Off (no water heating)
waterheatersystemaway_mode_durationDefines if away mode the duration in days.
waterheatersystemboost_mode_durationThe duration of the Boost mode in days. Valid from 1 to 7.
waterheatersystempower_heatpumpCurrent consumption/power of the heatpump in Watts.
waterheatersystempower_heatelecCurrent consumption/power of the electric resistance in Watts.
waterheatersystemshowersVirtual channel, representing the number of desired showers - between 3 to 5. It actually switches the desired temperature to 50.0, 54.5 or 62.0 Celcius degrees. Please note that in ECO mode, only 3 and 4 showers are allowed.
waterheatersystemheat_pump_operating_timeNumber of hours the heatpump has been operating
waterheatersystemelectric_booster_operating_timenumber of hours the electric booster has been operating.
waterheatersystemmodeThe current mode of the boiler. Can be: autoMode / manualEcoInactive / manualEcoActive
waterheatersystemtarget_temperatureWater target temperature in degrees. Read only. Temperature desired is managed through mode and showers channels.
hitachi (yutaki) air to water heating zone, dhw, main componentalarm_numbererror number in case of malfunction
hitachi (yutaki) air to water heating zonecircuit_controlcontrols the air-to-water-component (Run, Stop)
hitachi (yutaki) air to water heating zonecircuit_statusactual state of the air-to-water-component (Run, Stop)
hitachi (yutaki) air to water heating zoneholiday_modeswitch to activate the holiday mode
hitachi (yutaki) air to water heating zoneyutaki_modeactual mode of the heat pump (Eco, Comfort)
hitachi (yutaki) air to water heating zoneyutaki_target_modesets the mode of the heat pump (Eco, Comfort)
hitachi (yutaki) air to water heating zonezone_modesets the zone mode (Auto, Manual)
hitachi (yutaki) air to water heating zonethermostat_setting_zone1controls the thermostat setting for the zone 1
hitachi (yutaki) air to water heating zonewh_setting_temp_zone1controls the water heating setting temperature for the zone 1
hitachi (yutaki) air to water heating zoneroom_ambient_temp_zone1controls the room ambient temperature for the zone 1
hitachi (yutaki) domestic hot wateranti_legionellacontrols the anti legionella mode (Run, Stop)
hitachi (yutaki) domestic hot wateranti_legionella_tempcontrols the anti legionella temperature
hitachi (yutaki) domestic hot watertarget_boost_modecontrols the boost mode (No request, Enabled, Disabled)
hitachi (yutaki) domestic hot waterboost_modeboost mode status (Enabled, Disabled)
hitachi (yutaki) domestic hot waterdhwcontrols the hot water tank (Run, Stop)
hitachi (yutaki) domestic hot waterdhw_modecontrols the dhw mode (Standard, High demand)
hitachi (yutaki) domestic hot waterdhw_setting_tempcontrols the target temperature for hot water
hitachi (yutaki) domestic hot waterdhw_tempcurrent temperature of hot water
hitachi (yutaki) air to water main componentauto_manu_modecontrols auto/manual mode (Auto, Manual)
hitachi (yutaki) air to water main componentblock_menu_controlcontrols the block menu (No, Block)
hitachi (yutaki) air to water main componentcomm_alarm_bit_statusalarm bit status (No, Yes)
hitachi (yutaki) air to water main componentcompressor_running_currentstage of the current compressor running (0, 0.1, 0.2, 0.3, 0.4)
hitachi (yutaki) air to water main componenteco_mode_offsetoffset for the ECO-Mode
hitachi (yutaki) air to water main componenteco_mode_target_offsetcontrols the offset for the ECO-Mode (0-10 degrees)
hitachi (yutaki) air to water main componentliquid_tempcurrent liquid temperature
hitachi (yutaki) air to water main componentliquid_temp_thmicurrent liquid temperature THMI
hitachi (yutaki) air to water main componentoperationcurrent operation state (Alarm, Off, Heat/Cool thermo on, Heat/Cool thermo off, DHW off, Heat/Cool demand off, Swp off)
hitachi (yutaki) air to water main componentoutdoor_tempcurrent outdoor temperature
hitachi (yutaki) air to water main componentspace_modecontrols space mode (Eco, Comfort)
hitachi (yutaki) air to water main componentunit_controlcontrols unit (Run, Stop)
hitachi (yutaki) air to water main componentunit_mode_controlcontrols unit mode (Heat, Cool)
hitachi (yutaki) air to water main componentunit_mode_statusunit mode state (Heat, Cool)
hitachi (yutaki) air to water main componentwater_inlet_tempcurrent water inlet temperature
hitachi (yutaki) air to water main componentwater_outlet_tempcurrent water outlet temperature
hitachi (yutaki) air to water main componentwater_outlet_hp_tempcurrent water outlet hp temperature
hitachi (yutaki) air to water main componentwater_temp_settingtarget heating water temperature
hitachi (yutaki) air to water main componentyutaki_operating_modeyutaki operating mode (Auto, Holidays, Normal, Timer)

To run a scenario inside a rule for example, the ID of the scenario will be required. You can list all the scenarios IDs with the following console command: somfytahoma <bridgeUID> scenarios.

Remarks ​

All things which have a RSSI (received signal strength indication) state, expose a channel "rssi".

When a roller shutter-like Thing receives STOP command, there are two possible behaviours

  • when the roller shutter is idle then MY command is interpreted (the roller shutter/exterior screen/awning goes to your favourite position)
  • when the roller shutter is moving then STOP command is interpreted (the roller shutter/exterior screen/awning stops)

If you want to set the MY position of a roller shutter and you don't care the possible movement, try sending the MOVE command (OH2 does not know MY, so it stands for "move to MY position")

java
CONTROL_CHANNEL.sendCommand(MOVE)

Blinds and adjustable slats roller shutters can control their closure and orientation by sending a comma separated string consisting of closure (0-100) and orientation (0-100) to the "closure_orientaion" channel.

java
CLOSURE_ORIENTATION_CHANNEL.sendCommand("50,50")

Full Example ​

.things file

dsl
Bridge somfytahoma:bridge:237dbae7 "Somfy Tahoma Bridge" [ email="my@email.com", password="MyPassword", refresh=10 , statusTimeout=30] {
    Thing gateway 1214-4519-8041 "Tahoma gateway" [ id="1214-4519-8041" ]
    Thing rollershutter 31da8dac-8e09-455a-bc7a-6ed70f740001 "Bedroom" [ url="io://0204-1234-8041/6825356" ]
    Thing rollershutter 87bf0403-a45d-4037-b874-28f4ece30004 "Living room" [ url="io://0204-1234-8041/3832644" ]
    Thing rollershutter 68bee082-63ab-421d-9830-3ea561601234 "Hall" [ url="io://0204-1234-8041/4873641" ]
    Thing actiongroup 2104c46f-478d-6543-956a-10bd93b5dc54 "1st floor up" [ url="2104c46f-478d-6543-956a-10bd93b5dc54" ]
    Thing actiongroup 0b5f195a-5223-5432-b1af-f5fa1d59074f "1st floor down" [ url="0b5f195a-5223-5432-b1af-f5fa1d59074f" ]
    Thing actiongroup 712c0019-b422-1234-b4da-208e249c571b "2nd floor up" [ url="712c0019-b422-1234-b4da-208e249c571b" ]
    Thing actiongroup e201637b-de3b-1234-b7af-5693811a953b "2nd floor down" [ url="e201637b-de3b-1234-b7af-5693811a953b" ]
    Thing onoff 095d6c49-9712-4220-a4c3-d3bb7a6cc5f0 "Zwave switch" [ url="zwave://0204-4519-8041/5" ]
    Thing light 1b8e7d29-bf1e-4ae1-9432-3dfef52ef14d "Light switch" [ url="enocean://0204-4519-8041/4294453515/2" ]
    Thing lightsensor 2c90808c3a0c193f013a743f2f660f12 "Light sensor" [ url="io://0204-4519-8041/13527450" ]
    Thing occupancysensor 995e16ca-07c4-4111-9cda-504cb5120f82 "Occupancy sensor" [ url="io://0204-4519-8041/4855758" ]
    Thing smokesensor 9438e6ff-c17e-40d7-a4b4-3e797eca5bf7 "Smoke sensor" [ url="io://0204-4510-8041/13402124" ]
    Thing electricitysensor 9998e6ff-c17e-40d7-a4b4-3e797eca5bf7 "Electricity sensor" [ url="io://0204-4510-8041/288702124" ]
    Thing dock 1212f2e3-bcde-21dd-b3a6-13ef7abcd134 "Dock" [ url="io://0204-4510-8041/244402124" ]
    Thing siren 1212f2e3-aeae-21dd-b3a6-13ef7abcd134 "Siren" [ url="io://0204-4510-8041/244405678" ]
    Thing extheatingsystem 1212f2e3-aeae-21dd-b3a6-13ef7abcd155 "Ext heating system" [ url="io://0204-4510-8041/144405678" ]
}

Awnings, garage doors, screens, blinds, and windows things have the same notation as roller shutters. Just use "awning", "garagedoor", "screen", "blind" or "window" instead of "rolleshutter" in Thing definition.

.items file

dsl
String TahomaVersion "Tahoma version [%s]" { channel="somfytahoma:gateway:237dbae7:1214-4519-8041:version" }
Rollershutter RollerShutterBedroom "Roller shutter [%d %%]"  {channel="somfytahoma:rollershutter:237dbae7:31da8dac-8e09-455a-bc7a-6ed70f740001:control"}
Dimmer RollerShutterBedroomD "Roller shutter dimmer [%.1f]"  {channel="somfytahoma:rollershutter:237dbae7:31da8dac-8e09-455a-bc7a-6ed70f740001:control"}
Rollershutter RollerShutterLiving "Roller shutter [%d %%]"  {channel="somfytahoma:rollershutter:237dbae7:87bf0403-a45d-4037-b874-28f4ece30004:control" }
Dimmer RollerShutterLivingD "Roller shutter dimmer [%.1f]"  {channel="somfytahoma:rollershutter:237dbae7:87bf0403-a45d-4037-b874-28f4ece30004:control"}
Rollershutter RollerShutterHall "Roller shutter [%d %%]"  {channel="somfytahoma:rollershutter:237dbae7:68bee082-63ab-421d-9830-3ea561601234:control"}
Dimmer RollerShutterHallD "Roller shutter dimmer [%.1f]"  {channel="somfytahoma:rollershutter:237dbae7:68bee082-63ab-421d-9830-3ea561601234:control"}

Rollershutter AwningTerrace "Terrace awning [%d %%]"  {channel="somfytahoma:awning:237dbae7:24cee082-63ab-421d-9830-3ea561601234:control"}
Dimmer AwningTerraceD "Terrace awning dimmer [%.1f]"  {channel="somfytahoma:awning:237dbae7:24cee082-63ab-421d-9830-3ea561601234:control"}

Switch Rollers1UP "Rollers 1st floor UP" {channel="somfytahoma:actiongroup:237dbae7:2104c46f-478d-6543-956a-10bd93b5dc54:execute_action", autoupdate="false"}
Switch Rollers1DOWN "Rollers 1st floor DOWN" {channel="somfytahoma:actiongroup:237dbae7:0b5f195a-5223-5432-b1af-f5fa1d59074f:execute_action", autoupdate="false"}
Switch Rollers2UP "Rollers 2nd floor UP" {channel="somfytahoma:actiongroup:237dbae7:712c0019-b422-1234-b4da-208e249c571b:execute_action", autoupdate="false"}
Switch Rollers2DOWN "Rollers 2nd floor DOWN" {channel="somfytahoma:actiongroup:237dbae7:e201637b-de3b-1234-b7af-5693811a953b:execute_action", autoupdate="false"}

Switch TahomaZwaveSwitch "Switch" { channel="somfytahoma:onoff:237dbae7:095d6c49-9712-4220-a4c3-d3bb7a6cc5f0:switch" }
Switch TahomaLightSwitch "Light Switch" { channel="somfytahoma:light:237dbae7:1b8e7d29-bf1e-4ae1-9432-3dfef52ef14d:switch" }

Switch DimmerLightSwitch "Dimmer Light Switch" { channel="somfytahoma:dimmerlight:237dbae7:1b8e7d29-bf1e-4ae1-9432-3dfef52ef14e:light_intensity" }
Dimmer DimmerLightIntensity "Dimmer Light intensity [%.1f]"  {channel="somfytahoma:dimmerlight:237dbae7:1b8e7d29-bf1e-4ae1-9432-3dfef52ef14e:light_intensity"}

Number LightSensor "Light Sensor [%.1f lux]" { channel="somfytahoma:lightsensor:237dbae7:2c90808c3a0c193f013a743f2f660f12:luminance" }
Number:Energy EnergyConsumptionSensor "Energy Consumption [%.1f W]" { channel="somfytahoma:electricitysensor:237dbae7:9998e6ff-c17e-40d7-a4b4-3e797eca5bf7:energy_consumption" }

Contact OccupancySensor "Occupancy Sensor is [%s]" { channel="somfytahoma:occupancysensor:237dbae7:995e16ca-07c4-4111-9cda-504cb5120f82:contact" }
Contact SmokeSensor "Smoke Sensor is [%s]" { channel="somfytahoma:smokesensor:237dbae7:9438e6ff-c17e-40d7-a4b4-3e797eca5bf7:contact" }
Contact ContactSensor "Contact Sensor is [%s]" { channel="somfytahoma:contactsensor:237dbae7:6612f2e3-d23d-21dd-b3a6-13ef7abcd134:contact" }

Number TemperatureSensor "Temperature is [%2.1f °C]" { channel="somfytahoma:temperaturesensor:237dbae7:6612f2e3-d23d-21dd-b4a7-13ef7abcd134:temperature" }
String HeatingSystemLevel "Heating level [%s]" { channel="somfytahoma:onoffheatingsystem:237dbae7:6612f2e3-abcd-21dd-b3a6-13ef7abcd134:target_heating_level"}

Switch DoorLock "Lock" { channel="somfytahoma:doorlock:237dbae7:6612f2e3-bcde-21dd-b3a6-13ef7abcd134:lock" }
Switch DoorLockOpenClose "Open/Close" { channel="somfytahoma:doorlock:237dbae7:6612f2e3-bcde-21dd-b3a6-13ef7abcd134:open" }

String DockBatteryStatus "Dock battery status [%s]" { channel="somfytahoma:dock:237dbae7:1212f2e3-bcde-21dd-b3a6-13ef7abcd134:battery_status" }
String DockBatteryLevel "Dock battery level [%s]" { channel="somfytahoma:dock:237dbae7:1212f2e3-bcde-21dd-b3a6-13ef7abcd134:battery_level" }
String DockSiren "Dock siren [%s]" { channel="somfytahoma:dock:237dbae7:1212f2e3-bcde-21dd-b3a6-13ef7abcd134:siren" }
Switch DockShortBeep "Dock short beep" { channel="somfytahoma:dock:237dbae7:1212f2e3-bcde-21dd-b3a6-13ef7abcd134:short_beep" }
Switch DockLongBeep "Dock long beep" { channel="somfytahoma:dock:237dbae7:1212f2e3-bcde-21dd-b3a6-13ef7abcd134:long_beep" }

String SirenBattery "Siren battery [%s]" { channel="somfytahoma:siren:237dbae7:1212f2e3-aeae-21dd-b3a6-13ef7abcd134:battery" }
Switch SirenSwitch "Siren switch" { channel="somfytahoma:siren:237dbae7:1212f2e3-aeae-21dd-b3a6-13ef7abcd134:onoff" }
String SirenVolume "Siren volume [%s]" { channel="somfytahoma:siren:237dbae7:1212f2e3-aeae-21dd-b3a6-13ef7abcd134:memorized_volume" }

Dimmer HeatingLevel "Ext heating level [%.1f]"  { channel="somfytahoma:exteriorheatingsystem:237dbae7:1212f2e3-aeae-21dd-b3a6-13ef7abcd155:heating_level" }
Switch HeatingSwitch "Ext heating switch"  { channel="somfytahoma:exteriorheatingsystem:237dbae7:1212f2e3-aeae-21dd-b3a6-13ef7abcd155:heating_level" }

.sitemap file

dsl
Text item=TahomaVersion
Switch item=Rollers1UP label="Roller shutters 1st floor" mappings=[ON="UP"]
Switch item=Rollers1DOWN  label="Roller shutters 1st floor" mappings=[ON="DOWN"]
Switch item=Rollers2UP label="Roller shutters 2nd floor" mappings=[ON="UP"]
Switch item=Rollers2DOWN  label="Roller shutters 2nd floor" mappings=[ON="DOWN"]
Switch item=RollerShutterBedroom
Slider item=RollerShutterBedroomD
Switch item=RollerShutterLiving
Slider item=RollerShutterLivingD
Switch item=TahomaZwaveSwitch
Switch item=TahomaLightSwitch
Switch item=DimmerLightSwitch
Slider item=DimmerLightIntensity
Text item=LightSensor
Text item=OccupancySensor
Text item=SmokeSensor
Text item=ContactSensor
Text item=TemperatureSensor
Text item=ElectricitySensor
Switch item=HeatingSystemOnOff
Selection item=HeatingSystemLevel mappings=["frostprotection"="FROST PROTECTION", "comfort"="COMFORT", "eco"="ECO", "off"="OFF"]
Switch item=DoorLock
Switch item=DoorLockOpenClose
Text item=DockBatteryStatus
Text item=DockBatteryLevel
Selection item=DockSiren mappings=["off"="OFF", "on"="ON", "cyclic"="CYCLIC"]
Switch item=DockShortBeep
Switch item=DockLongBeep
String item=SirenBattery
Switch item=SirenSwitch
Selection item=SirenVolume mappings=["normal"="NORMAL", "highest"="HIGHEST"]
Slider item=HeatingLevel

Alexa compatibility ​

This binding is compatible with the official Alexa Smart Home Skill. Since Rollershutter items are unsupported, only Dimmer with control channel can be used. Syntax in .item file is as follows:

dsl
Dimmer RollerShutterLivingD "Roller shutter living [%.1f]"  [ "Lighting" ] {channel="somfytahoma:rollershutter:237dbae7:87bf0403-a45d-4037-b874-28f4ece30004:control"}

Alexa can set the roller shutter (awning, blind, ...) to a specific position as well as send ON (interpreted as UP) and OFF commands (interpreted as DOWN).