# Hayward Omnilogic Binding

The Hayward Omnilogic binding integrates the Omnilogic pool controller using the Hayward API.

The Hayward Omnilogic API interacts with Hayward's cloud server requiring a connection with the Internet for sending and receiving information.

# Supported Things

The table below lists the Hayward OmniLogic binding thing types:

Things Description Thing Type
Hayward OmniLogix Connection Connection to Hayward's Server bridge
Backyard Backyard backyard
Body of Water Body of Water bow
Chlorinator Chlorinator chlorinator
Colorlogic Light Colorlogic Light colorlogic
Filter Filter control filter
Heater Equipment Actual heater (i.e. gas, solar, electric) heater
Pump Auxillary pump control (i.e. spillover) pump
Relay Accessory relay control (deck jet sprinklers, lights, etc.) relay
Virtaul Heater A Virtual Heater that can control all of the heater equipment based on priority virtualHeater

# Discovery

The binding will automatically discover the Omnilogic pool things from the cloud server using your Hayward Omnilogic credentials.

# Thing Configuration

Hayward OmniLogic Connection Parameters:

Property Default Required Description
Host Name https://app1.haywardomnilogic.com/HAAPI/HomeAutomation/API.ash (opens new window) Yes Host name of the Hayward API server
User Name None Yes Your Hayward User Name (not email address)
Password None Yes Your Hayward User Password
Telemetry Poll Delay 3 Yes Telemetry Poll Delay (2-60 seconds)
Alarm Poll Delay 10 Yes Alarm Poll Delay (0-120 seconds, 0 disabled)

# Channels

# Backyard Channels

Channel Type ID Item Type Description Read Write
backyardAirTemp Number:Temperature Backyard air temp sensor reading R
backyardStatus String Backyard status R
backyardState String Backyard state R
backyardAlarm1 String Backyard alarm #1 R
backyardAlarm2 String Backyard alarm #2 R
backyardAlarm3 String Backyard alarm #3 R
backyardAlarm4 String Backyard alarm #4 R
backyardAlarm5 String Backyard alarm #5 R

# Body of Water Channels

Channel Type ID Item Type Description Read Write
bowFlow Switch Body of Water flow sensor feedback R
bowWaterTemp Number:Temperature Body of Water temperature R

# Chlorinator Channels

Channel Type ID Item Type Description Read Write
chlorEnable Switch Chlorinator enable R/W
chlorOperatingMode String Chlorinator operating mode R
chlorTimedPercent Number:Dimensionless Chlorinator salt output (%) R/W
chlorOperatingState Number Chlorinator operating state R
chlorScMode String Chlorinator super chlorinate mode R
chlorError String Chlorinator error bit array R
chlorAlert String Chlorinator alert bit array R
chlorAvgSaltLevel Number:Dimensionless Chlorinator average salt level in Part per Million (ppm) R
chlorInstantSaltLevel Number:Dimensionless Chlorinator instant salt level in Part per Million (ppm) R
chlorStatus String Chlorinator status bit array R

# Chlorinator Error Bit Array

Bits Value Description
1:0 00 = OK
01 = Short
10 = Open
Current Sensor
3:2 00 = OK
01 = Short
10 = Open
Voltage Sensor
5:4 00 = OK
01 = Short
10 = Open
Cell Temp Sensor
7:6 00 = OK
01 = Short
10 = Open
Board Temp Sensor
9:8 00 = OK
01 = Short
10 = Open
K1 Relay
11:10 00 = OK
01 = Short
10 = Open
K2 Relay
13:12 00 = OK
01 = Type
10 = Authentication
11 = Comm Loss
Cell Errors
14 0 Aquarite PCB Error

# Chlorinator Alert Bit Array

Bits Value Description
1:0 00 = OK
01 = Salt Low
10 = Salt too Low
Low salt
2 0 = OK
1 = High
High Current
3 0 = OK
1 = Low
Low Voltage
5:4 00 = OK
01 = Low
10 = Scaleback
11 = High
Cell Water Temp
7:6 00 = OK
01 = High
10 = Clearing
Board Temp
8 0 Not Used
10:9 0 Not Used
12:11 00 = OK
01 = Clean
Cell Cleaning/Runtime

# Chlorinator Status Bit Array

Bits Value Description
0 0 = OK
1 = Error Present
Error Present
1 0 = OK
1 = Alert Present
Alert Present
2 0 = Standy
1 = Generating
Generating
3 0 = Not Paused
1 = Paused
Paused
4 0 = Local Not Paused
1 = Local Paused
Local Pause
5 0 = Not Authenticated<>

1 = Authenticated
T-Cell Authenticated
6 0 = K1 Relay Off
1 = K1 Relay On
K1 Relay Active
7 0 = K2 Relay Off
1 = K2 Relay On
K2 Relay Active

# Colorlogic Light Channels

Channel Type ID Item Type Description Read Write
colorLogicLightEnable Switch Colorlogic Light enable R/W
colorLogicLightState String Colorlogic Light state R
colorLogicLightCurrentShow String Colorlogic Light current show R/W
colorLogicLightBrightness String Colorlogic Light brightness R/W
colorLogicLightSpeed String Colorlogic Light speed R/W

**Brightness and speed channels only available on Hayward V2 lights

# Filter Channels

Channel Type ID Item Type Description Read Write
filterEnable Switch Filter enable R/W
filterValvePosition String Filter valve position R
filterSpeedPercent Number:Dimensionless Filter speed (%) R/W
filterSpeedRpm Number:Frequency Filter speed (rpm) R/W
filterSpeedSelect String Filter speed presets R/W
filterState String Filter state R
filterLastSpeed Number:Dimensionless Filter last speed (%) R

# Heater Channels

Channel Type ID Item Type Description Read Write
heaterState String Heater state R
heaterEnable Switch Heater enable R

# Pump Channels

Channel Type ID Item Type Description Read Write
pumpEnable Switch Pump enable R/W
pumpSpeedPercent Number:Dimensionless Pump speed (%) R/W
pumpSpeedRpm Number: Frequency Pump speed in rpm R/W
pumpSpeedSelect String Pump speed presets R/W
pumpState String Pump state R
pumpLastSpeed Number:Dimensionless Pump last speed (%) R

# Relay Channels

Channel Type ID Item Type Description Read Write
relayState Switch Relay state R/W

# Virtual Heater Channels

Channel Type ID Item Type Description Read Write
heaterEnable Switch Heater enable R
heaterCurrentSetpoint Number:Temperature Heater Current Setpoint R/W

**Item Types Number:Dimensionless should have the units (i.e. %, ppm) defined in the Unit metadata

# Full Example

After installing the binding, you will need to manually add the Hayward Connection thing and enter your credentials. All pool items can be automatically discovered by scanning the bridge. Goto the inbox and add the things.