SP103 Motion Detector
This describes the Z-Wave device SP103, manufactured by Everspring with the thing type UID of everspring_sp103_00_000
.
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The SP103 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The SP103 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
Motion Detector
Inclusion Information
Press the tamper switch on the detector to complete the inclusion process.
Exclusion Information
Press the tamper switch on the detector to complete the exclusion process.
Wakeup Information
The SP103 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press the tamper switch on the detector to wake the device for 10 minutes.
Channels
The following table summarises the channels available for the SP103 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Binary Sensor
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the SP103. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Phase level on command | Defines which command to send when sensor triggers |
2 | Enable/Disable Sleeping | Enables/Disables sleeping for debug purposes |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Parameter 1: Phase level on command
Defines which command to send when sensor triggers
The following option values may be configured -:
Value | Description |
---|---|
0 | Set OFF |
1 | Set ON |
9 | Set LAST Level |
The manufacturer defined default value is 0
(Set OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Enable/Disable Sleeping
Enables/Disables sleeping for debug purposes
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SP103 supports 1 association group.
Group 1: Triggered Report
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.