# Solarman Logger Binding

Binding used to communicate with Solarman (IGEN-Tech) v5 based solar inverter data loggers in direct-mode over the local network. More information about the different types of stick loggers is available on the Solarman (opens new window) site.

These data loggers are used by inverters from a lot of manufacturers, just to name a few:

  • Deye
  • Sofar
  • Solis
  • ZCS Azzurro
  • KStar

# Supported Things

The solarman:logger thing supports reading data from a Solarman LSW-3 Stick Logger (it might also work with LSE-3 and maybe others) when connected to a supported inverter.

It was tested on a SUN-12K-SG04LP3-EU only, but because the implementation uses the inverter definitions created as part of Stephan Joubert's Home Assistant plugin it might work with the other inverters supported by the plugin.

# Thing Configuration

To connect the logger you need the IP address of the logger and its serial number. The IP address can be obtained from your router and the serial number can either be read from the label of the logger, or by connecting to the logger with a browser (default user/pass: admin/admin) and getting it from the Status page. Please note that you need the "Device serial number" from the "Device information" section, not the "Inverter serial number".

# logger Thing Configuration

Name Type Description Default Required Advanced
hostname text Hostname or IP address of the Solarman logger N/A yes no
serialNumber text Serial number of the Solarman logger N/A yes no
inverterType text The type of inverter connected to the logger N/A yes no
port integer Port of the Solarman logger 8899 no yes
refreshInterval integer Interval the device is polled in sec. 60 no yes
additionalRequests text Additional requests besides the ones in the definition N/A no yes

The inverterType parameter governs what registers the binding will read from the logger and what channels it will expose.

Possible values:

Inverter Type Inverters supported Notes
deye_hybrid DEYE/Sunsynk/SolArk Hybrid inverters used when no lookup specified
deye_sg04lp3 DEYE/Sunsynk/SolArk Hybrid 8/12K-SG04LP3 e.g. 12K-SG04LP3-EU
deye_string DEYE/Sunsynk/SolArk String inverters e.g. SUN-4/5/6/7/8/10/12K-G03 Plus
deye_2mppt DEYE Microinverter with 2 MPPT Trackers e.g. SUN600G3-EU-230 / SUN800G3-EU-230 / SUN1000G3-EU-230
deye_4mppt DEYE Microinverter with 4 MPPT Trackers e.g. SUN1300G3-EU-230 / SUN1600G3-EU-230 / SUN2000G3-EU-230
sofar_lsw3 SOFAR Inverters
sofar_g3hyd SOFAR Hybrid Three-Phase inverter HYD 6000 or rebranded (three-phase), ex. ZCS Azzurro 3PH HYD-ZSS
sofar_hyd3k-6k-es SOFAR Hybrid Single-Phase inverter HYD 6000 or rebranded (single-phase), ex. ZCS Azzurro HYD-ZSS
solis_hybrid SOLIS Hybrid inverter
solid_1p8k-5g SOLIS 1P8K-5G
solis_3p-4g SOLIS Three-Phase Inverter 4G Series
solis_s6-gr1p SOLIS Single-Phase Inverter S6-GR1P
hyd-zss-hp-3k-6k ZCS Azzurro Hybrid HP 3K-6K inverters Rebranded Sofar models
kstar_hybrid KSTAR Hybrid inverters
sofar_wifikit SOFAR WiFi Kit
zcs_azzurro-ktl-v3 ZCS Azzurro KTL-V3 inverters ZCS Azzurro 3.3/4.4/5.5/6.6 KTL-V3 (rebranded Sofar KTLX-G3)

The additionalRequests allows the user to specify additional address ranges to be polled. The format of the value is mb_functioncode1:start1-end1, mb_functioncode2:start2-end2,... For example "0x03:0x27D-0x27E" will issue an additional read for Holding Registers between 0x27D and 0x27E.

This is useful when coupled with user defined channels, for example a thing definition like the one below will also read the register for the AC frequency on a Deye inverter, besides the ones pre-defined in the deye_sg04lp3 inverter definition.

Thing solarman:logger:local [ hostname="x.x.x.x", inverterType="deye_sg04lp3", serialNumber="1234567890", additionalRequests="0x03:0x27D-0x27E" ] {
        Channels:
            Type number : inverter-frequency [scale="0.01", uom="Hz", rule="3", registers="0x27E"]
}

Please note As of this writing inverter types besides the deye_sg04lp3 were not tested to work. If you have one of those inverters and it works, please drop me a message, if it doesn't work, please open an issue and I'll try to fix it.

# Channels

The list of channels is not static, it is generated dynamically based on the inverter type selected.

This is the list you get for the deye_sg04lp3 inverter type:

Channel Type Read/Write Description
alert-alert Number R Alert [0x0229,0x022A,0x022B,0x022C,0x022D,0x022E]
battery-battery-current Number R Battery Current [0x024F]
battery-battery-power Number R Battery Power [0x024E]
battery-battery-soc Number R Battery SOC [0x024C]
battery-battery-temperature Number R Battery Temperature [0x024A]
battery-battery-voltage Number R Battery Voltage [0x024B]
battery-daily-battery-charge Number R Daily Battery Charge [0x0202]
battery-daily-battery-discharge Number R Daily Battery Discharge [0x0203]
battery-total-battery-charge Number R Total Battery Charge [0x0204,0x0205]
battery-total-battery-discharge Number R Total Battery Discharge [0x0206,0x0207]
battery-battery-absorption-v Number R Battery Absorption V [0x0064]
battery-battery-empty-v Number R Battery Empty V [0x0066]
battery-battery-equalization-v Number R Battery Equalization V [0x0063]
battery-battery-float-v Number R Battery Float V [0x0065]
battery-battery-capacity Number R Battery Capacity [0x0066]
battery-battery-max-a-charge Number R Battery Max A Charge [0x006C]
battery-battery-max-a-discharge Number R Battery Max A Discharge [0x006D]
grid-daily-energy-bought Number R Daily Energy Bought [0x0208]
grid-daily-energy-sold Number R Daily Energy Sold [0x0209]
grid-external-ct-l1-power Number R External CT L1 Power [0x0268]
grid-external-ct-l2-power Number R External CT L2 Power [0x0269]
grid-external-ct-l3-power Number R External CT L3 Power [0x026A]
grid-grid-voltage-l1 Number R Grid Voltage L1 [0x0256]
grid-grid-voltage-l2 Number R Grid Voltage L2 [0x0257]
grid-grid-voltage-l3 Number R Grid Voltage L3 [0x0258]
grid-internal-ct-l1-power Number R Internal CT L1 Power [0x025C]
grid-internal-ct-l2-power Number R Internal CT L2 Power [0x025D]
grid-internal-ct-l3-power Number R Internal CT L3 Power [0x025E]
grid-total-energy-bought Number R Total Energy Bought [0x020A,0x020B]
grid-total-energy-sold Number R Total Energy Sold [0x020C,0x020D]
grid-total-grid-power Number R Total Grid Power [0x0271]
grid-total-grid-production Number R Total Grid Production [0x020C,0x020D]
inverter-ac-temperature Number R AC Temperature [0x021D]
inverter-communication-board-version-no- Number R Communication Board Version No [0x0011]
inverter-control-board-version-no- Number R Control Board Version No [0x000D]
inverter-current-l1 Number R Current L1 [0x0276]
inverter-current-l2 Number R Current L2 [0x0277]
inverter-current-l3 Number R Current L3 [0x0278]
inverter-dc-temperature Number R DC Temperature [0x021C]
inverter-frequency Number R Inverter Frequency [0x27E]
inverter-inverter-id String R Inverter ID [0x0003,0x0004,0x0005,0x0006,0x0007]
inverter-inverter-l1-power Number R Inverter L1 Power [0x0279]
inverter-inverter-l2-power Number R Inverter L2 Power [0x027A]
inverter-inverter-l3-power Number R Inverter L3 Power [0x027B]
solar-daily-production Number R Daily Production [0x0211]
solar-pv1-current Number R PV1 Current [0x02A5]
solar-pv1-power Number R PV1 Power [0x02A0]
solar-pv1-voltage Number R PV1 Voltage [0x02A4]
solar-pv2-current Number R PV2 Current [0x02A7]
solar-pv2-power Number R PV2 Power [0x02A1]
solar-pv2-voltage Number R PV2 Voltage [0x02A6]
solar-total-production Number R Total Production [0x0216,0x0217]
upload-daily-load-consumption Number R Daily Load Consumption [0x020E]
upload-load-l1-power Number R Load L1 Power [0x028A]
upload-load-l2-power Number R Load L2 Power [0x028B]
upload-load-l3-power Number R Load L3 Power [0x028C]
upload-load-voltage-l1 Number R Load Voltage L1 [0x0284]
upload-load-voltage-l2 Number R Load Voltage L2 [0x0285]
upload-load-voltage-l3 Number R Load Voltage L3 [0x0286]
upload-total-load-consumption Number R Total Load Consumption [0x020F,0x0210]
upload-total-load-power Number R Total Load Power [0x028D]

# Full Example

This is an example for a DEYE 12kW (SUN-12K-SG04LP3-EU) hybrid inverter

# solarman.things

Please replace the hostname and serialNumber with the correct values for your logger.

Thing solarman:logger:local [hostname="x.x.x.x",inverterType="deye_sg04lp3",serialNumber="1234567890"]

# solarman.items

Items file example for a SUN-12K-SG04LP3-EU inverter

Number:Temperature        AC_Temperature                  "AC Temperature [%.1f °C]"             (solarman)  {channel="solarman:logger:local:inverter-ac-temperature", unit="°C"}
Number                    Alert                           "Alert [%s]"                           (solarman)  {channel="solarman:logger:local:alert-alert"}
Number:ElectricPotential  Battery_Absorption_V            "Battery Absorption V [%.2f V]"        (solarman)  {channel="solarman:logger:local:battery-battery-absorption-v", unit="V"}
Number:ElectricCharge     Battery_Capacity                "Battery Capacity [%d Ah]"             (solarman)  {channel="solarman:logger:local:battery-battery-capacity", unit="Ah"}
Number:ElectricCurrent    Battery_Current                 "Battery Current [%.1f A]"             (solarman)  {channel="solarman:logger:local:battery-battery-current", unit="A"}
Number:Energy             Daily_Battery_Charge            "Daily Battery Charge [%.1f kWh]"      (solarman)  {channel="solarman:logger:local:battery-daily-battery-charge", unit="kWh"}
Number:Energy             Daily_Battery_Discharge         "Daily Battery Discharge [%.1f kWh]"   (solarman)  {channel="solarman:logger:local:battery-daily-battery-discharge", unit="kWh"}
Number:ElectricPotential  Battery_Empty_V                 "Battery Empty V [%.2f V]"             (solarman)  {channel="solarman:logger:local:battery-battery-empty-v", unit="V"}
Number:ElectricPotential  Battery_Equalization_V          "Battery Equalization V [%.2f V]"      (solarman)  {channel="solarman:logger:local:battery-battery-equalization-v", unit="V"}
Number:ElectricPotential  Battery_Float_V                 "Battery Float V [%.2f V]"             (solarman)  {channel="solarman:logger:local:battery-battery-float-v", unit="V"}
Number:ElectricCurrent    Battery_Max_A_Charge            "Battery Max A Charge [%d A]"          (solarman)  {channel="solarman:logger:local:battery-battery-max-a-charge", unit="A"}
Number:ElectricCurrent    Battery_Max_A_Discharge         "Battery Max A Discharge [%d A]"       (solarman)  {channel="solarman:logger:local:battery-battery-max-a-discharge", unit="A"}
Number:Dimensionless      Battery_SOC                     "Battery SOC [%d %%]"                  (solarman)  {channel="solarman:logger:local:battery-battery-soc", unit="%"}
Number:Power              Battery_Power                   "Battery Power [%d W]"                 (solarman)  {channel="solarman:logger:local:battery-battery-power", unit="W"}
Number:Temperature        Battery_Temperature             "Battery Temperature [%.1f °C]"        (solarman)  {channel="solarman:logger:local:battery-battery-temperature", unit="°C"}
Number:ElectricPotential  Battery_Voltage                 "Battery Voltage [%.2f V]"             (solarman)  {channel="solarman:logger:local:battery-battery-voltage", unit="V"}
Number:Dimensionless      Communication_Board_Version_No  "Communication Board Version No [%s]"  (solarman)  {channel="solarman:logger:local:inverter-communication-board-version-no-"}
Number:Dimensionless      Control_Board_Version_No        "Control Board Version No [%s]"        (solarman)  {channel="solarman:logger:local:inverter-control-board-version-no-"}
Number:ElectricCurrent    Current_L1                      "Current L1 [%.1f A]"                  (solarman)  {channel="solarman:logger:local:inverter-current-l1", unit="A"}
Number:ElectricCurrent    Current_L2                      "Current L2 [%.1f A]"                  (solarman)  {channel="solarman:logger:local:inverter-current-l2", unit="A"}
Number:ElectricCurrent    Current_L3                      "Current L3 [%.1f A]"                  (solarman)  {channel="solarman:logger:local:inverter-current-l3", unit="A"}
Number:Energy             Daily_Energy_Bought             "Daily Energy Bought [%d kWh]"         (solarman)  {channel="solarman:logger:local:grid-daily-energy-bought", unit="kWh"}
Number:Energy             Daily_Energy_Sold               "Daily Energy Sold [%d Wh]"            (solarman)  {channel="solarman:logger:local:grid-daily-energy-sold", unit="Wh"}
Number:Energy             Daily_Load_Consumption          "Daily Load Consumption [%.1f kWh]"    (solarman)  {channel="solarman:logger:local:upload-daily-load-consumption", unit="kWh"}
Number:Energy             Daily_Production                "Daily Production [%.1f kWh]"          (solarman)  {channel="solarman:logger:local:solar-daily-production", unit="kWh"}
Number:Temperature        DC_Temperature                  "DC Temperature [%.1f °C]"             (solarman)  {channel="solarman:logger:local:inverter-dc-temperature", unit="°C"}
Number:Power              External_CT_L1_Power            "External CT L1 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-external-ct-l1-power", unit="W"}
Number:Power              External_CT_L2_Power            "External CT L2 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-external-ct-l2-power", unit="W"}
Number:Power              External_CT_L3_Power            "External CT L3 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-external-ct-l3-power", unit="W"}
Number:Power              Gen_Port_A_Phase_Power          "Phase Power of Gen Port A [%d W]"     (solarman)  {channel="solarman:logger:local:smartload-phase-power-of-gen-port-a", unit="W"}
Number:Power              Gen_Port_B_Phase_Power          "Phase Power of Gen Port B [%d W]"     (solarman)  {channel="solarman:logger:local:smartload-phase-power-of-gen-port-b", unit="W"}
Number:Power              Gen_Port_C_Phase_Power          "Phase Power of Gen Port C [%d W]"     (solarman)  {channel="solarman:logger:local:smartload-phase-power-of-gen-port-c", unit="W"}
Number:ElectricPotential  Gen_Port_A_Phase_Voltage        "Phase Voltage of Gen Port A [%d V]"   (solarman)  {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-a", unit="V"}
Number:ElectricPotential  Gen_Port_B_Phase_Voltage        "Phase Voltage of Gen Port B [%d V]"   (solarman)  {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-b", unit="V"}
Number:ElectricPotential  Gen_Port_C_Phase_Voltage        "Phase Voltage of Gen Port C [%d V]"   (solarman)  {channel="solarman:logger:local:smartload-phase-voltage-of-gen-port-c", unit="V"}
String                    Inverter_Id                     "Inverter Id [%s]"                     (solarman)  {channel="solarman:logger:local:inverter-inverter-id"}
Number:Power              Inverter_L1_Power               "Inverter L1 Power [%d W]"             (solarman)  {channel="solarman:logger:local:inverter-inverter-l1-power", unit="W"}
Number:Power              Inverter_L2_Power               "Inverter L2 Power [%d W]"             (solarman)  {channel="solarman:logger:local:inverter-inverter-l2-power", unit="W"}
Number:Power              Inverter_L3_Power               "Inverter L3 Power [%d W]"             (solarman)  {channel="solarman:logger:local:inverter-inverter-l3-power", unit="W"}
Number:Power              Internal_CT_L1_Power            "Internal CT L1 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-internal-ct-l1-power", unit="W"}
Number:Power              Internal_CT_L2_Power            "Internal CT L2 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-internal-ct-l2-power", unit="W"}
Number:Power              Internal_CT_L3_Power            "Internal CT L3 Power [%d W]"          (solarman)  {channel="solarman:logger:local:grid-internal-ct-l3-power", unit="W"}
Number:ElectricPotential  Load_Voltage_L1                 "Load Voltage L1 [%d V]"               (solarman)  {channel="solarman:logger:local:upload-load-voltage-l1", unit="V"}
Number:ElectricPotential  Load_Voltage_L2                 "Load Voltage L2 [%d V]"               (solarman)  {channel="solarman:logger:local:upload-load-voltage-l2", unit="V"}
Number:ElectricPotential  Load_Voltage_L3                 "Load Voltage L3 [%d V]"               (solarman)  {channel="solarman:logger:local:upload-load-voltage-l3", unit="V"}
Number:Power              Load_L1_Power                   "Load L1 Power [%d W]"                 (solarman)  {channel="solarman:logger:local:upload-load-l1-power", unit="W"}
Number:Power              Load_L2_Power                   "Load L2 Power [%d W]"                 (solarman)  {channel="solarman:logger:local:upload-load-l2-power", unit="W"}
Number:Power              Load_L3_Power                   "Load L3 Power [%d W]"                 (solarman)  {channel="solarman:logger:local:upload-load-l3-power", unit="W"}
Number:ElectricPotential  Grid_Voltage_L1                 "Grid Voltage L1 [%d V]"               (solarman)  {channel="solarman:logger:local:grid-grid-voltage-l1", unit="V"}
Number:ElectricPotential  Grid_Voltage_L2                 "Grid Voltage L2 [%d V]"               (solarman)  {channel="solarman:logger:local:grid-grid-voltage-l2", unit="V"}
Number:ElectricPotential  Grid_Voltage_L3                 "Grid Voltage L3 [%d V]"               (solarman)  {channel="solarman:logger:local:grid-grid-voltage-l3", unit="V"}
Number:Energy             Generator_Daily_Power_Generation "Generator Daily Power Generation [%.1f kWh]" (solarman) {channel="solarman:logger:local:smartload-generator-daily-power-generation", unit="kWh"}
Number:Energy             Generator_Total_Power_Generation "Generator Total Power Generation [%.1f kWh]" (solarman) {channel="solarman:logger:local:smartload-generator-total-power-generation", unit="kWh"}
Number:Dimensionless      Smartload_Enable_Status         "Smartload Enable Status [%d]"         (solarman)  {channel="solarman:logger:local:smartload-smartload-enable-status"}
Number:Energy             Total_Battery_Charge            "Total Battery Charge [%d kWh]"        (solarman)  {channel="solarman:logger:local:battery-total-battery-charge", unit="kWh"}
Number:Energy             Total_Battery_Discharge         "Total Battery Discharge [%d kWh]"     (solarman)  {channel="solarman:logger:local:battery-total-battery-discharge", unit="kWh"}
Number:Energy             Total_Energy_Bought             "Total Energy Bought [%d kWh]"         (solarman)  {channel="solarman:logger:local:grid-total-energy-bought", unit="kWh"}
Number:Energy             Total_Energy_Sold               "Total Energy Sold [%d kWh]"           (solarman)  {channel="solarman:logger:local:grid-total-energy-sold", unit="kWh"}
Number:Power              Total_Gen_Port_Power            "Total Power of Gen Port [%d W]"       (solarman)  {channel="solarman:logger:local:smartload-total-power-of-gen-port", unit="W"}
Number:Power              Total_Grid_Power                "Total Instant Grid Power [%d W]"      (solarman)  {channel="solarman:logger:local:grid-total-grid-power", unit="W"}
Number:Energy             Total_Grid_Production           "Total Grid Feed-in [%.1f kWh]"        (solarman)  {channel="solarman:logger:local:grid-total-grid-production", unit="kWh"}
Number:Energy             Total_Load_Consumption          "Total Load Consumption [%d kWh]"      (solarman)  {channel="solarman:logger:local:upload-total-load-consumption", unit="kWh"}
Number:Power              Total_Load_Power                "Total Load Power [%d W]"              (solarman)  {channel="solarman:logger:local:upload-total-load-power", unit="W"}
Number:Energy             Total_Solar_Production          "Total Solar Production [%.1f kWh]"    (solarman)  {channel="solarman:logger:local:solar-total-production", unit="kWh"}
Number:Power              PV1_Power                       "PV1 Power [%d W]"                     (solarman)  {channel="solarman:logger:local:solar-pv1-power", unit="W"}
Number:ElectricCurrent    PV1_Current                     "PV1 Current [%.1f A]"                 (solarman)  {channel="solarman:logger:local:solar-pv1-current", unit="A"}
Number:ElectricPotential  PV1_Voltage                     "PV1 Voltage [%d V]"                   (solarman)  {channel="solarman:logger:local:solar-pv1-voltage", unit="V"}
Number:Power              PV2_Power                       "PV2 Power [%d W]"                     (solarman)  {channel="solarman:logger:local:solar-pv2-power", unit="W"}
Number:ElectricCurrent    PV2_Current                     "PV2 Current [%.1f A]"                 (solarman)  {channel="solarman:logger:local:solar-pv2-current", unit="A"}
Number:ElectricPotential  PV2_Voltage                     "PV2 Voltage [%d V]"                   (solarman)  {channel="solarman:logger:local:solar-pv2-voltage", unit="V"}

Number:Frequency          Inverter_Frequency              "Inverter Frequency [%.2f Hz]"         (solarman)  {channel="solarman:logger:local:inverter-frequency", unit="Hz"}

# solarman.sitemap

Sitemap example for a SUN-12K-SG04LP3-EU inverter

sitemap solarman label="Solarman"
{
    Frame label="Inverter"{
        Text item=Communication_Board_Version_No icon="solar"
        Text item=Control_Board_Version_No icon="solar"
        Text item=Inverter_Id icon="solar"
        Text item=AC_Temperature icon="temperature"
        Text item=DC_Temperature icon="temperature"
        Text item=Inverter_L1_Power icon="poweroutlet"
        Text item=Inverter_L2_Power icon="poweroutlet"
        Text item=Inverter_L3_Power icon="poweroutlet"
        Text item=Current_L1 icon="line"
        Text item=Current_L2 icon="line"
        Text item=Current_L3 icon="line"
        Text item=Inverter_Frequency icon="line"
    }

    Frame label="Battery"{
        Text item=Battery_SOC icon="battery"
        Text item=Battery_Current icon="current"
        Text item=Battery_Power icon="power"
        Text item=Battery_Voltage icon="voltage"
        Text item=Battery_Temperature icon="temperature"
        Text item=Daily_Battery_Charge icon="renewable"
        Text item=Daily_Battery_Discharge icon="battery"
        Text item=Total_Battery_Charge icon="renewable"
        Text item=Total_Battery_Discharge icon="battery"
        Text item=Battery_Absorption_V icon="voltage"
        Text item=Battery_Equalization_V icon="voltage"
        Text item=Battery_Float_V icon="voltage"
        Text item=Battery_Empty_V icon="voltage"
        Text item=Battery_Capacity icon="battery"
        Text item=Battery_Max_A_Charge icon="battery"
        Text item=Battery_Max_A_Discharge icon="battery"
    }

    Frame label="Solar"{
        Text item=Total_Solar_Production icon="solar"
        Text item=Daily_Production icon="solar"
        Text item=PV1_Current icon="solar"
        Text item=PV1_Power icon="solar"
        Text item=PV1_Voltage icon="solar"
        Text item=PV2_Current icon="solar"
        Text item=PV2_Power icon="solar"
        Text item=PV2_Voltage icon="solar"
    }

    Frame label="Grid"{
        Text item=Total_Grid_Production icon="power"
        Text item=Total_Grid_Power icon="power"
        Text item=External_CT_L1_Power icon="power"
        Text item=External_CT_L2_Power icon="power"
        Text item=External_CT_L3_Power icon="power"
        Text item=Internal_CT_L1_Power icon="power"
        Text item=Internal_CT_L2_Power icon="power"
        Text item=Internal_CT_L3_Power icon="power"
        Text item=Grid_Voltage_L1 icon="power"
        Text item=Grid_Voltage_L2 icon="power"
        Text item=Grid_Voltage_L3 icon="power"
        Text item=Daily_Energy_Sold icon="power"
        Text item=Total_Energy_Sold icon="power"
        Text item=Daily_Energy_Bought icon="power"
        Text item=Total_Energy_Bought icon="power"
    }

    Frame label="Load"{
        Text item=Daily_Load_Consumption icon="power"
        Text item=Total_Load_Consumption icon="power"
        Text item=Load_L1_Power icon="power"
        Text item=Load_L2_Power icon="power"
        Text item=Load_L3_Power icon="power"
        Text item=Load_Voltage_L1 icon="power"
        Text item=Load_Voltage_L2 icon="power"
        Text item=Load_Voltage_L3 icon="power"
        Text item=Total_Load_Power icon="power"
    }

    Frame label="Generator"{
        Text item=Gen_Port_A_Phase_Power icon="poweroutlet"
        Text item=Gen_Port_B_Phase_Power icon="poweroutlet"
        Text item=Gen_Port_C_Phase_Power icon="poweroutlet"
        Text item=Gen_Port_A_Phase_Voltage icon="voltage"
        Text item=Gen_Port_B_Phase_Voltage icon="voltage"
        Text item=Gen_Port_C_Phase_Voltage icon="voltage"
        Text item=Total_Gen_Port_Power icon="power"
        Text item=Generator_Daily_Power_Generation icon="power"
        Text item=Generator_Total_Power_Generation icon="power"
    }

    Frame label="Alert"{
        Text item=Alert icon="alert"
    }
}

# Acknowledgments

The code's creation draws significant inspiration from Stephan Joubert's Home Assistant plugin (opens new window), which provides the inverter definitions used in the project. Additionally, the pysolarmanv5 module (opens new window) was a valuable resource, as it offers an excellent explanation of the Solarman V5 protocol.