# Warmup Binding

This binding integrates Warmup (opens new window) Wifi enabled Thermostats via the API at https://my.warmup.com/ (opens new window).

Devices known to work with the binding:

Device expected to work with the binding:

Devices which might work with the binding:

Any Warmup device must be registered at https://my.warmup.com/ (opens new window) prior to usage, or connected through the MyHeating app (opens new window).

This API is not known to be documented publicly. The binding api implementation has been derived from the implementations at https://github.com/alyc100/SmartThingsPublic/blob/master/devicetypes/alyc100/warmup-4ie.src/warmup-4ie.groovy (opens new window) and https://github.com/alex-0103/warmup4IE/blob/master/warmup4ie/warmup4ie.py (opens new window), and enhanced by inspecting the GraphQL endpoint (opens new window).

# Supported Things

The Warmup binding supports the following thing types:

Bridge Label Description
my-warmup My Warmup Account The account credentials for my.warmup.com (opens new window) which acts as an API to the Warmup device(s)
Thing Label Description
room Room A room containing an individual Warmup WiFi connected device which controls a heating circuit.

Room The device is optimised for controlling underfloor heating (electric or hydronic), although it can also control central heating circuits. The device reports the temperature from one of two thermostats, either a floor temperature probe or the air temperature at the device. It appears to be possible to configure two devices in a primary / secondary configuration, but it is not clear how this might be represented by the API and hasn't been implemented.

# Discovery

Once credentials are successfully added to the bridge, any rooms (devices) detected will be added as things to the inbox.

# Thing Configuration

# my-warmup Bridge Configuration

config parameter type description required default
username String Username for my.warmup.com (opens new window) true
password String Password for my.warmup.com (opens new window) true
refreshInterval Integer Interval in seconds between automatic refreshes true 300

# room Thing Configuration

Rooms are configured automatically with a Serial Number on discovery, or can be added manually using the "Device Number" from the device, excluding the last 3 characters. Changing the target temperature results in a temporary override to that temperature, for the duration configured on the thing. This defaults to 60 minutes.

config parameter type description required default
serialNumber String Device Serial Number, excluding last 3 characters true
overrideDuration Integer Duration in minutes of override when target temperature is changed false 60

# Channels

channel type description read only
currentTemperature Number:Temperature Currently reported temperature true
targetTemperature Number:Temperature Target temperature false
overrideRemaining Number:Time Duration remaining of the configured override true
fixedTemperature Number:Temperature Target temperature for fixed mode false
energyToday Number:Energy Today's current energy consumption. true
runMode String Current operating mode of the thermostat, options listed below false
frostProtectionMode Switch Toggles between the "Frost Protection" run mode and the previously configured "active" run mode (known options are either Fixed or Schedule) false
airTemperature Number:Temperature Currently reported air temperature at the device true
floor1Temperature Number:Temperature Currently reported temperature from floor probe 1 on the device true
floor2Temperature Number:Temperature Currently reported temperature from floor probe 2 on the device true

# Run Mode Statuses

These run mode statuses are defined for the API. The descriptions are based on inspection of the device behaviour and are not sourced from documentation. Only the value schedule is writeable, this reverts the device to the program/schedule configured on the device. The value fixed can be set by commanding the fixedTemperature channel. The value override can be set by commanding the targetTemperature channel.

api value ui name description
not_set Not Set Unknown
off Off Device turned off
schedule Schedule Device target temperature running to a programmed schedule
override Override Target temperature overridden for the remaining duration in overrideRemaining
fixed Fixed Device target temperature set to a constant fixed value
anti_frost Frost Protection Device target temperature set to 7°C
holiday Holiday Device target temperature set to a constant fixed value for duration of holiday
fil_pilote Fil Pilote Unknown
gradual Gradual Unknown
relay Relay Unknown
previous Previous Unknown

# Rule Actions

# setOverride(temperature, duration)

Sets a temporary temperature override on the device

Parameters:

Name Type Description
temperature QuantityType Override temperature. Must be between 5°C and 30°C
duration QuantityType Duration of the override. Must be between 0 and 1440 minutes (24 hours)

Example:

    # Full Example

    # .things file

    Bridge warmup:my-warmup:MyWarmup [ username="[email protected]", password="test", refreshInterval=300 ]
    {
        room    bathroom    "Home - Bathroom"   [ serialNumber="AABBCCDDEEFF", overrideDuration=60 ]
    }
    

    # .items file

    Number:Temperature bathroom_temperature "Temperature [%.1f °C]" <temperature> (GF_Bathroom, Temperature)    ["Temperature"] {channel="warmup:room:MyWarmup:bathroom:currentTemperature"}
    Number:Temperature bathroom_setpoint    "Set Point [%.1f °C]" <temperature> (GF_Bathroom) ["Set Point"] {channel="warmup:room:MyWarmup:bathroom:targetTemperature"}
    Number:Time bathroom_overrideRemaining  "Override Remaining [%d minutes]" (GF_Bathroom) {channel="warmup:room:MyWarmup:bathroom:overrideRemaining"}
    String bathroom_runMode "Run Mode [%s]" (GF_Bathroom) {channel="warmup:room:MyWarmup:bathroom:runMode"}
    Switch bathroom_frostProtection "Frost Protection Mode" (GF_Bathroom) {channel="warmup:room:MyWarmup:bathroom:frostProtectionMode"}
    

    # Sitemap

    Text label="Bathroom" {
        Text item=bathroom_temperature
        Setpoint item=bathroom_setpoint step=0.5
        Text item=bathroom_overrideRemaining
        Text item=bathroom_runMode
        Switch item=bathroom_frostProtection
    }