myVAILLANT Binding
This binding connects Vaillant heating systems (e.g. aroTHERM plus heat pumps) with a sensoCOMFORT controller (VRC720) to openHAB through the myVAILLANT cloud, the backend of the myVAILLANT app. The API client is based on myPyllant.
Limitations
- Only systems with the control identifier
tli(sensoCOMFORT VRC720 with a VR920/VR921/VR940f gateway) are supported. Systems with a VRC700 (vrc700) or iQconnect (scf) controller go offline with a configuration error. - ambiSENSE rooms, ventilation units and EEBUS are not supported. Time programs can be read and written as JSON with the actions.
- Vaillant limits the number of requests per account (call volume quota). When it is exceeded, the API answers with
Out of call volume quotafor up to an hour and the binding pauses all requests until then. All clients of an account share the quota, e.g. the myVAILLANT app and other integrations.
Supported Things
| Thing Type | Description |
|---|---|
account | Bridge for the myVAILLANT account, logs in and pauses requests while the quota is exceeded |
system | Bridge for one system (a home in the app), reads the whole system in one update |
zone | A zone (rooms controlled together) |
circuit | A heating circuit with flow temperature and heating curve |
dhw | Domestic hot water |
device | A device of the system, e.g. the heat pump or the electric backup heater |
Discovery
After adding the account bridge, its systems appear in the inbox. After adding a system bridge, its zones, circuits, hot water and devices appear in the inbox. Discovery uses the data of the regular updates and causes (almost) no additional requests.
Thing Configuration
account Bridge
| Name | Type | Description | Default | Required | Advanced |
|---|---|---|---|---|---|
username | text | Email address of the myVAILLANT account | N/A | yes | no |
password | text | Password of the account | N/A | yes | no |
brand | text | vaillant, sdbg (Saunier Duval), bulex, glow-worm or demirdokum | vaillant | yes | no |
country | text | Country of the account (Vaillant and Saunier Duval) in lower case letters, e.g. germany, austria, unitedkingdom | germany | no | no |
refreshInterval | integer | Seconds between updates of the systems (at least 60) | 300 | no | no |
energyRefreshInterval | integer | Minutes between updates of today's energy values, 0 disables them | 60 | no | no |
fetchRts | boolean | Read operation time and on/off cycles of the devices (one request per update) | false | no | no |
fetchMpc | boolean | Read the current power of the devices (one request per update) | false | no | no |
fetchConnectionStatus | boolean | Read whether the system is online (one request per update) | false | no | yes |
fetchTroubleCodes | boolean | Read the diagnostic trouble codes (one request per update) | false | no | yes |
refreshDelay | integer | Seconds to wait after a command before updating, the API takes a while to show new values | 10 | no | yes |
quickVetoDurationInHours | decimal | Hours a temperature set outside of manual mode (quick veto) lasts | 3 | no | no |
holidayDurationInDays | integer | Days away mode lasts when switched on without an end | 365 | no | yes |
manualCoolingDurationInDays | integer | Days manual cooling lasts when switched on without an end | 30 | no | yes |
Each update of a system costs two requests (system state, and the device list at most every 30 minutes) plus one for each fetch... option. Energy values cost one request per linked energy channel and update.
system Bridge
| Name | Type | Description | Required |
|---|---|---|---|
systemId | text | ID of the system, filled in by discovery | yes |
zone, circuit and dhw Things
| Name | Type | Description | Required |
|---|---|---|---|
index | integer | Index of the zone or circuit (the first one is 0), hot water usually has index 255 | yes |
device Thing
| Name | Type | Description | Required |
|---|---|---|---|
deviceUuid | text | ID of the device, filled in by discovery | yes |
Channels
account
| Channel | Type | Read/Write | Description |
|---|---|---|---|
api-requests | Number | R | Requests sent to Vaillant today (advanced) |
system
| Channel | Type | Read/Write | Description |
|---|---|---|---|
outdoor-temperature | Number:Temperature | R | Outdoor temperature |
outdoor-temperature-average-24h | Number:Temperature | R | Average outdoor temperature of the last 24 hours |
water-pressure | Number:Pressure | R | Water pressure of the system |
system-flow-temperature | Number:Temperature | R | Flow temperature of the system |
cylinder-temperature-top-dhw | Number:Temperature | R | Top temperature of the hot water cylinder |
cylinder-temperature-bottom-dhw | Number:Temperature | R | Bottom temperature of the hot water cylinder |
cylinder-temperature-top-ch | Number:Temperature | R | Top temperature of the heating buffer |
cylinder-temperature-bottom-ch | Number:Temperature | R | Bottom temperature of the heating buffer |
energy-manager-state | String | R | STANDBY, HEATING, DHW or COOLING |
system-off | Switch | R | Whether the system is switched off |
holiday | Switch | RW | Away mode, ON starts it now for holidayDurationInDays days |
holiday-start | DateTime | RW | Start of away mode |
holiday-end | DateTime | RW | End of away mode |
manual-cooling | Switch | RW | Cooling for days, ON starts it now for manualCoolingDurationInDays days |
manual-cooling-start | DateTime | R | Start of manual cooling |
manual-cooling-end | DateTime | RW | End of manual cooling |
ventilation-boost | Switch | RW | Ventilation boost |
heating-energy-efficiency | Number | R | Heat generated per consumed electrical energy for heating today, all devices |
firmware-update-required | Switch | R | Whether a firmware update is required |
online | Switch | R | Whether the system is connected (needs fetchConnectionStatus) |
trouble-codes | String | R | Diagnostic trouble codes (needs fetchTroubleCodes) |
has-trouble-codes | Switch | R | Whether there are trouble codes (needs fetchTroubleCodes) |
last-update | DateTime | R | Time of the last successful update (advanced) |
zone
| Channel | Type | Read/Write | Description |
|---|---|---|---|
current-room-temperature | Number:Temperature | R | Room temperature measured by the controller |
current-room-humidity | Number:Dimensionless | R | Humidity measured by the controller |
desired-room-temperature-setpoint | Number:Temperature | RW | Current target temperature, a command sets the manual mode setpoint in manual mode, else a quick veto |
desired-room-temperature-setpoint-heating | Number:Temperature | R | Current target temperature for heating |
desired-room-temperature-setpoint-cooling | Number:Temperature | R | Current target temperature for cooling |
operation-mode-heating | String | RW | TIME_CONTROLLED, MANUAL or OFF |
operation-mode-cooling | String | RW | TIME_CONTROLLED, MANUAL or OFF |
manual-mode-setpoint-heating | Number:Temperature | RW | Target temperature in manual mode |
setpoint-cooling | Number:Temperature | RW | Target temperature for cooling |
set-back-temperature | Number:Temperature | RW | Temperature outside of the time windows in time controlled mode |
heating-state | String | R | IDLE, HEATING_UP or COOLING_DOWN |
current-special-function | String | R | NONE, QUICK_VETO, HOLIDAY, SYSTEM_OFF, VENTILATION_BOOST or ONE_DAY_BANK_HOLIDAY |
hvac-action | String | R | idle, heating or cooling, the state of the zone's circuit |
quick-veto | Switch | RW | Quick veto, ON starts it with the manual mode setpoint for quickVetoDurationInHours hours |
quick-veto-end | DateTime | R | End of the quick veto |
quick-veto-duration | Number:Time | RW | Remaining time of the quick veto, a command sets a new duration |
manual-cooling-active | Switch | R | Whether manual cooling is active |
circuit
| Channel | Type | Read/Write | Description |
|---|---|---|---|
circuit-state | String | R | HEATING, COOLING or STANDBY |
current-flow-temperature | Number:Temperature | R | Current flow temperature |
flow-temperature-setpoint | Number:Temperature | R | Target flow temperature |
heating-curve | Number | RW | Slope of the heating curve |
heat-demand-limited-by-outside-temperature | Number:Temperature | RW | No heat demand above this outdoor temperature |
min-flow-temperature-setpoint | Number:Temperature | RW | Minimum flow temperature |
max-flow-temperature-setpoint | Number:Temperature | R | Maximum flow temperature |
room-temperature-control-mode | String | R | Influence of the room temperature, e.g. NON (advanced) |
calculated-energy-manager-state | String | R | State of the energy manager for the circuit (advanced) |
cooling-allowed | Switch | R | Whether the circuit may cool |
dhw
| Channel | Type | Read/Write | Description |
|---|---|---|---|
current-temperature | Number:Temperature | R | Temperature of the hot water |
tapping-setpoint | Number:Temperature | RW | Target temperature, whole degrees |
operation-mode | String | RW | TIME_CONTROLLED, MANUAL or OFF |
current-special-function | String | R | REGULAR, CYLINDER_BOOST, HOLIDAY or SYSTEM_OFF |
boost | Switch | RW | Heats the cylinder once now |
device
| Channel | Type | Read/Write | Description |
|---|---|---|---|
current-power | Number:Power | R | Current electrical power (needs fetchMpc) |
operation-time | Number:Time | R | Total operation time in hours (needs fetchRts) |
on-off-cycles | Number | R | Total number of starts (needs fetchRts) |
water-pressure | Number:Pressure | R | Water pressure measured by the device, if it has a sensor |
heating-energy-efficiency | Number | R | Heat generated per consumed electrical energy for heating today |
In addition, the binding adds a Number:Energy channel with today's value for every energy value the device reports, named after value type and operation mode, e.g.
consumed-electrical-energy-heating,consumed-electrical-energy-domestic-hot-water,consumed-electrical-energy-coolingheat-generated-heating,heat-generated-domestic-hot-waterearned-environment-energy-heating,earned-environment-energy-domestic-hot-waterconsumed-primary-energy-heating(gas boilers)
Today means since midnight in the time zone of the system. Only linked energy channels are updated.
Actions
The actions are available for rules as actions.thingActions('myvaillant', '<thing UID>') (JavaScript) or getActions("myvaillant", "<thing UID>") (DSL).
system
| Action | Description |
|---|---|
exportEnergyData(resolution, start, end, operationMode) | Energy values of all devices as JSON, null on errors |
setHoliday(start, end) | Sets away mode, empty start means now, empty end the configured duration |
cancelHoliday() | Ends away mode |
setCoolingForDays(start, end) | Cools manually between start and end |
cancelCoolingForDays() | Ends manual cooling |
refresh() | Updates the system after the refresh delay |
resolution is HOUR (at most 3 days per call), DAY (at most 60 days) or MONTH. start and end are dates like 2026-11-01, 2026-11-01 00:00:00 or ISO dates, without offset they are in the time zone of the system. operationMode limits the export to HEATING, DOMESTIC_HOT_WATER or COOLING; every device and value type costs one request, so limit it where possible.
The result is a JSON array with one entry per device:
[
{
"device": {
"device_uuid": "...",
"name": "aroTHERM plus",
"device_type": "HEATPUMP",
"type": "primary_heat_generator"
},
"data": [
{
"operation_mode": "HEATING",
"energy_type": "CONSUMED_ELECTRICAL_ENERGY",
"resolution": "DAY",
"total_consumption": 33600.0,
"data": [
{
"start_date": "2026-11-12T01:00:00+01:00",
"end_date": "2026-11-13T01:00:00+01:00",
"value": 33600.0
}
]
}
]
}
]Values are in Wh.
zone
| Action | Description |
|---|---|
setQuickVeto(temperature, durationHours) | Starts or changes a quick veto, empty duration uses quickVetoDurationInHours |
cancelQuickVeto() | Ends the quick veto |
setManualModeSetpoint(temperature, type) | Sets the manual mode setpoint, type HEATING (default) or COOLING |
getTimeProgram(type) | Time program as JSON, type heating (default) or cooling |
setTimeProgram(type, timeProgram) | Sets the time program from JSON in the format of getTimeProgram |
Time programs contain the weekdays monday ... sunday, each with a list of slots with startTime and endTime in minutes after midnight and setpoint in °C.
dhw
| Action | Description |
|---|---|
getTimeProgram() | Hot water time program as JSON |
setTimeProgram(timeProgram) | Sets the hot water time program |
getCirculationTimeProgram() | Circulation pump time program as JSON |
setCirculationTimeProgram(timeProgram) | Sets the circulation pump time program |
Full Example
demo.things
Bridge myvaillant:account:vaillant "myVAILLANT" [ username="user@example.com", password="secret", brand="vaillant", country="germany", refreshInterval=300, fetchRts=true, fetchMpc=true ] {
Bridge system home "Heat Pump" [ systemId="0123456789abcdef" ] {
Thing zone zone0 "Heat Pump Zone" [ index=0 ]
Thing circuit circuit0 "Heat Pump Circuit" [ index=0 ]
Thing device primary-heat-generator "Heat Pump" [ deviceUuid="..." ]
Thing device electric-backup-heater "Backup Heater" [ deviceUuid="..." ]
}
}demo.items
Number:Temperature Outdoor_Temperature "Outdoor [%.1f °C]" { channel="myvaillant:system:vaillant:home:outdoor-temperature" }
Number:Temperature Room_Target "Target [%.1f °C]" { channel="myvaillant:zone:vaillant:home:zone0:desired-room-temperature-setpoint" }
String Heating_Mode "Mode [%s]" { channel="myvaillant:zone:vaillant:home:zone0:operation-mode-heating" }
Number:Temperature Flow_Temperature "Flow [%.1f °C]" { channel="myvaillant:circuit:vaillant:home:circuit0:current-flow-temperature" }
Number:Power HeatPump_Power "Power [%d W]" { channel="myvaillant:device:vaillant:home:primary-heat-generator:current-power" }
Number:Energy HeatPump_Heating "Heating today [%.1f kWh]" { channel="myvaillant:device:vaillant:home:primary-heat-generator:consumed-electrical-energy-heating" }demo.js
const vaillant = actions.thingActions(
"myvaillant",
"myvaillant:system:vaillant:home",
);
const json = vaillant.exportEnergyData(
"DAY",
"2026-11-01",
"2026-11-20 23:59:59",
"HEATING",
);
if (json !== null) {
JSON.parse(json).forEach((device) =>
console.info(device.device.name, device.data.length),
);
}